Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2005-04-01 → 2005-04-30 |
| Other | Monitoring | Resolved | 2012-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2025 |
| Bromodichloromethane | 5.6 µg/L No EPA limit set | 8/8 | SYR4 | 2012–2019 |
| Chloroform | 46.6 µg/L No EPA limit set | 8/8 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 6.7 µg/L No EPA limit set | 8/8 | SYR4 | 2012–2019 |
| TTHM | 51.6 µg/L 65% of the EPA limit 80 µg/L | 8/8 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 19.3 µg/L 32% of the EPA limit 60 µg/L | 8/8 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 13.9 µg/L No EPA limit set | 8/8 | SYR4 | 2012–2019 |
| Dibromochloromethane | 0.6000 µg/L No EPA limit set | 1/8 | SYR4 | 2012–2019 |
4 contaminants tested, none detected
Utility contact
Frequently asked questions about Lwwsd - Eagleridge
Is Lwwsd - Eagleridge tap water safe to drink?
EPA monitoring detected 8 contaminants in Lwwsd - Eagleridge's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Lwwsd - Eagleridge's water?
EPA monitoring detected Lead, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.
How many people does Lwwsd - Eagleridge serve?
Lwwsd - Eagleridge reports serving 196 people in Washington, per its EPA record.
Has Lwwsd - Eagleridge had any water quality violations?
The EPA has 2 violations on file for Lwwsd - Eagleridge, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.