← Washington

Tap water quality report

Prairie Ridge 605

EPA monitoring tested this supplier for 48 contaminants and detected 3. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

48
contaminants tested
3
detected
250
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Thurston

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-10-01 → 2023-10-31
MR Monitoring Resolved 1997-07-01 → 1998-07-01
MR Monitoring Archived 1993-04-01 → 1993-04-30
MR Monitoring Archived 1992-10-01 → 1992-10-31
MR Monitoring Archived 1992-09-01 → 1992-09-30
MR Monitoring Archived 1979-10-01 → 1979-10-31
MR Monitoring Archived 1979-10-01 → 1979-10-31
MR Monitoring Archived 1979-10-01 → 1979-10-31
MR Monitoring Archived 1979-10-01 → 1979-10-31
MR Monitoring Archived 1979-10-01 → 1979-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3700 µg/L 37%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Nitrate-Nitrite
3700 µg/L 37%
of the EPA limit 10000 µg/L
1/1 SYR4 2016
45 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicBariumBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChloroformChromiumDichloromethaneDalaponDibromochloromethaneDinosebEthylbenzeneFluorideLeadMercuryNitritePentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Kimberly Gubbe

Frequently asked questions about Prairie Ridge 605

Is Prairie Ridge 605 tap water safe to drink?

EPA monitoring detected 3 contaminants in Prairie Ridge 605's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Prairie Ridge 605's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite. The full list with the level and data source for each is above.

How many people does Prairie Ridge 605 serve?

Prairie Ridge 605 reports serving 250 people in Washington, per its EPA record.

Has Prairie Ridge 605 had any water quality violations?

The EPA has 13 violations on file for Prairie Ridge 605, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.