Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MON | Monitoring | Resolved | 2024-10-01 → 2024-10-31 |
| MON | Monitoring | Resolved | 2024-10-01 → 2024-10-31 |
| MON | Monitoring | Resolved | 2024-10-01 → 2024-10-31 |
| MON | Monitoring | Resolved | 2024-10-01 → 2024-10-31 |
| MR | Monitoring | Resolved | 2023-01-01 |
| MR | Monitoring | Resolved | 2023-01-01 |
| MR | Monitoring | Resolved | 2019-01-01 → 2019-12-31 |
| MR | Monitoring | Resolved | 2019-01-01 → 2019-12-31 |
| MR | Monitoring | Resolved | 2019-01-01 → 2019-12-31 |
| MR | Monitoring | Resolved | 2019-01-01 → 2019-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 230 µg/L 2.3% of the EPA limit 10000 µg/L | 26/30 | SYR4 | 2012–2019 |
| Copper | 1100 µg/L 85% of the EPA limit 1300 µg/L | 15/26 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 16.6 pCi/L No EPA limit set | 10/10 | SYR4 | 2013–2017 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 10/10 | LCR | 2025 |
| Lead | 8.02 µg/L 53% of the EPA limit 15 µg/L | 7/26 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 14.7 pCi/L 294% of the EPA limit, in the worst sample — 5 pCi/L | 6/6 | SYR4 | 2015–2017 |
| Barium | 63 µg/L 3.2% of the EPA limit 2000 µg/L | 2/6 | SYR4 | 2013–2018 |
| Bromodichloromethane | 0.7000 µg/L No EPA limit set | 2/17 | SYR4 | 2012–2019 |
| Chloroform | 1.1 µg/L No EPA limit set | 2/17 | SYR4 | 2012–2019 |
| TTHM | 1.8 µg/L 2.3% of the EPA limit 80 µg/L | 2/8 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 9.8 µg/L No EPA limit set | 1/8 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 21.9 pCi/L 146% of the EPA limit, in the worst sample — 15 pCi/L | 1/1 | SYR4 | 2017 |
| Toluene | 3.8 µg/L 0.4% of the EPA limit 1000 µg/L | 1/10 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 9.8 µg/L 16% of the EPA limit 60 µg/L | 1/8 | SYR4 | 2013–2019 |
38 contaminants tested, none detected
Utility contact
Frequently asked questions about i-77 Exit 1
Is i-77 Exit 1 tap water safe to drink?
EPA monitoring detected 14 contaminants in i-77 Exit 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in i-77 Exit 1's water?
EPA monitoring detected Nitrate-Nitrite, Copper, Gross Beta Particle Activity, Lead, Lead, and others. The full list with the level and data source for each is above.
How many people does i-77 Exit 1 serve?
i-77 Exit 1 reports serving 325 people in Virginia, per its EPA record.
Has i-77 Exit 1 had any water quality violations?
The EPA has 18 violations on file for i-77 Exit 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.