← Utah

Tap water quality report

Orangeville

EPA monitoring tested this supplier for 74 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
14
detected
1,420
people served
3
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Emery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
369
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
Other Monitoring Resolved 2017-10-01
Other Monitoring Resolved 2017-10-01
Other Monitoring Resolved 2017-10-01
MON Monitoring Resolved 2016-12-01 → 2016-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
78.12 µg/L 98%
of the EPA limit 80 µg/L
worst single sample: 112.4 µg/L
69/73 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
31.7 µg/L 53%
of the EPA limit 60 µg/L
worst single sample: 49.7 µg/L
66/73 SYR4 2012–2019
Bromodichloromethane
6.15 µg/L
No EPA limit set
worst single sample: 8.4 µg/L
56/61 SYR4 2012–2019
Chloroform
76.525 µg/L
No EPA limit set
worst single sample: 108.3 µg/L
56/61 SYR4 2012–2019
Dichloroacetic Acid
19.07 µg/L
No EPA limit set
worst single sample: 27.6 µg/L
52/58 SYR4 2012–2019
Trichloroacetic Acid
17.74 µg/L
No EPA limit set
worst single sample: 22.1 µg/L
52/58 SYR4 2012–2019
Copper
350.065 µg/L 27%
of the EPA limit 1300 µg/L
worst single sample: 441 µg/L
30/30 SYR4 2013–2019
Lead
3.74 µg/L 25%
of the EPA limit 15 µg/L
worst single sample: 4.1 µg/L
27/30 SYR4 2013–2019
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Dibromochloromethane
1.335 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
14/61 SYR4 2012–2019
Arsenic
1.17 µg/L 12%
of the EPA limit 10 µg/L
worst single sample: 1.2 µg/L
3/3 SYR4 2013–2019
Barium
84.97 µg/L 4.2%
of the EPA limit 2000 µg/L
worst single sample: 85 µg/L
3/3 SYR4 2013–2019
Cyanide
2 µg/L 1%
of the EPA limit 200 µg/L
1/3 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.6 pCi/L 11%
of the EPA limit 15 pCi/L
1/2 SYR4 2014–2017
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEndrinEthylbenzeneFluorideGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SHARP, JACOB
Phone
435-381-5333
Email
JSHARP@ETV.NET

Frequently asked questions about Orangeville

Is Orangeville tap water safe to drink?

EPA monitoring detected 14 contaminants in Orangeville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Orangeville's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Orangeville serve?

Orangeville reports serving 1,420 people in Utah, per its EPA record.

Has Orangeville had any water quality violations?

The EPA has 369 violations on file for Orangeville, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.