← Utah

Tap water quality report

Huntington - Castle Valley Ssd

EPA monitoring tested this supplier for 74 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
18
detected
2,129
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Emery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
85
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
Other Monitoring Resolved 2017-10-01
Other Monitoring Resolved 2017-10-01
Other Monitoring Resolved 2017-10-01
MR Monitoring Resolved 2010-01-01 → 2010-12-31
MR Monitoring Resolved 2010-01-01 → 2010-12-31
MR Monitoring Resolved 2010-01-01 → 2010-12-31
MR Monitoring Resolved 2009-01-01 → 2009-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
150.05 µg/L 12%
of the EPA limit 1300 µg/L
worst single sample: 332 µg/L
30/30 SYR4 2013–2019
Lead
3.41 µg/L 23%
of the EPA limit 15 µg/L
worst single sample: 10.6 µg/L
27/30 SYR4 2013–2019
Barium
102.72 µg/L 5.1%
of the EPA limit 2000 µg/L
worst single sample: 107 µg/L
25/25 SYR4 2013–2019
Lead
0.0024 mg/L 16%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
TTHM
9.245 µg/L 12%
of the EPA limit 80 µg/L
worst single sample: 10 µg/L
22/22 SYR4 2012–2019
Selenium
1.1 µg/L 2.2%
of the EPA limit 50 µg/L
worst single sample: 1.4 µg/L
21/25 SYR4 2013–2019
Bromodichloromethane
2.345 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
18/18 SYR4 2012–2019
Dibromochloromethane
1.375 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
18/18 SYR4 2012–2019
Chloroform
3.82 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
17/18 SYR4 2012–2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
17/25 SYR4 2013–2019
Nitrate
200 µg/L 2%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Cyanide
3 µg/L 1.5%
of the EPA limit 200 µg/L
7/25 SYR4 2013–2019
Dichloroacetic Acid
1.68 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
2/16 SYR4 2012–2019
Cadmium
0.3000 µg/L 6%
of the EPA limit 5 µg/L
1/25 SYR4 2013–2019
Chromium
76 µg/L 76%
of the EPA limit 100 µg/L
1/26 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.2 pCi/L 8%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Gross Beta Particle Activity
0.6500 pCi/L
No EPA limit set
1/1 SYR4 2019
Mercury
0.5000 µg/L 25%
of the EPA limit 2 µg/L
1/25 SYR4 2013–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SHARP, JACOB
Phone
435-381-5333
Email
JSHARP@ETV.NET

Frequently asked questions about Huntington - Castle Valley Ssd

Is Huntington - Castle Valley Ssd tap water safe to drink?

EPA monitoring detected 18 contaminants in Huntington - Castle Valley Ssd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Huntington - Castle Valley Ssd's water?

EPA monitoring detected Copper, Lead, Barium, Lead, TTHM, and others. The full list with the level and data source for each is above.

How many people does Huntington - Castle Valley Ssd serve?

Huntington - Castle Valley Ssd reports serving 2,129 people in Utah, per its EPA record.

Has Huntington - Castle Valley Ssd had any water quality violations?

The EPA has 85 violations on file for Huntington - Castle Valley Ssd, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.