Tap water quality report

Ferron - Castle Valley Ssd

EPA monitoring tested this supplier for 76 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
24
detected
1,660
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Emery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
176
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2019-12-30
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
57.72 µg/L
No EPA limit set
worst single sample: 90.6 µg/L
133/134 SYR4 2012–2019
Bromodichloromethane
9.205 µg/L
No EPA limit set
worst single sample: 11.7 µg/L
120/129 SYR4 2012–2019
TTHM
61.82 µg/L 77%
of the EPA limit 80 µg/L
worst single sample: 94.8 µg/L
73/73 SYR4 2012–2019
Dibromochloromethane
2.92 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
69/115 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.1 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 21.5 µg/L
61/74 SYR4 2012–2019
Trichloroacetic Acid
9.54 µg/L
No EPA limit set
worst single sample: 13 µg/L
53/62 SYR4 2012–2019
Toluene
13 µg/L 1.3%
of the EPA limit 1000 µg/L
worst single sample: 22.9 µg/L
41/111 SYR4 2012–2019
Dichloroacetic Acid
4 µg/L
No EPA limit set
worst single sample: 8.5 µg/L
38/61 SYR4 2012–2019
Xylenes, Total
12.35 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 31.5 µg/L
35/114 SYR4 2012–2019
Copper
489.9 µg/L 38%
of the EPA limit 1300 µg/L
worst single sample: 518.5 µg/L
30/30 SYR4 2013–2019
Benzene
7.9735 µg/L 159%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 8.7 µg/L
28/116 SYR4 2012–2019
Lead
9.575 µg/L 64%
of the EPA limit 15 µg/L
worst single sample: 26.4 µg/L
26/30 SYR4 2013–2019
Nitrate
214.45 µg/L 2.1%
of the EPA limit 10000 µg/L
worst single sample: 217 µg/L
24/36 SYR4 2012–2019
Lead
0.0022 mg/L 15%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Ethylbenzene
2.68 µg/L 0.4%
of the EPA limit 700 µg/L
worst single sample: 4 µg/L
12/120 SYR4 2012–2019
Barium
115.925 µg/L 5.8%
of the EPA limit 2000 µg/L
worst single sample: 116.1 µg/L
6/6 SYR4 2016–2019
Chlorobenzene
2.3075 µg/L 2.3%
of the EPA limit 100 µg/L
worst single sample: 2.33 µg/L
6/121 SYR4 2012–2019
Dichloromethane
10.25 µg/L 205%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 11 µg/L
6/121 SYR4 2012–2019
Gross Beta Particle Activity
4.275 pCi/L
No EPA limit set
worst single sample: 4.6 pCi/L
6/8 SYR4 2017–2018
Selenium
0.9750 µg/L 2%
of the EPA limit 50 µg/L
worst single sample: 1 µg/L
6/6 SYR4 2016–2019
Arsenic
0.9800 µg/L 9.8%
of the EPA limit 10 µg/L
worst single sample: 1 µg/L
5/5 SYR4 2016–2019
Fluoride
226.96 µg/L 5.7%
of the EPA limit 4000 µg/L
worst single sample: 229.2 µg/L
5/5 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
1.495 pCi/L 10%
of the EPA limit 15 pCi/L
worst single sample: 1.6 pCi/L
4/8 SYR4 2017–2018
Bromoform
0.6900 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
3/130 SYR4 2012–2019
52 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzo(A)PyreneBeryllium, TotalCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEndrinHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SHARP, JACOB
Phone
435-381-5333
Email
JSHARP@ETV.NET

Frequently asked questions about Ferron - Castle Valley Ssd

Is Ferron - Castle Valley Ssd tap water safe to drink?

EPA monitoring detected 24 contaminants in Ferron - Castle Valley Ssd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ferron - Castle Valley Ssd's water?

EPA monitoring detected Chloroform, Bromodichloromethane, TTHM, Dibromochloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Ferron - Castle Valley Ssd serve?

Ferron - Castle Valley Ssd reports serving 1,660 people in Utah, per its EPA record.

Has Ferron - Castle Valley Ssd had any water quality violations?

The EPA has 176 violations on file for Ferron - Castle Valley Ssd, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.