← Texas

Tap water quality report

Sharon Wsc

EPA monitoring tested this supplier for 109 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
29
detected
9,111
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Wood

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
23
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1991-04-01 → 1991-04-30
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
66.5 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 110 µg/L
122/132 SYR4 2012–2019
Copper
551.8 µg/L 42%
of the EPA limit 1300 µg/L
worst single sample: 1130 µg/L
117/134 SYR4 2012–2018
Chloroform
27.22 µg/L
No EPA limit set
worst single sample: 34.1 µg/L
77/80 SYR4 2012–2019
Bromodichloromethane
20.62 µg/L
No EPA limit set
worst single sample: 27.8 µg/L
73/80 SYR4 2012–2019
Dibromochloromethane
27.54 µg/L
No EPA limit set
worst single sample: 42.6 µg/L
73/80 SYR4 2012–2019
Lead
2.272 µg/L 15%
of the EPA limit 15 µg/L
worst single sample: 7.67 µg/L
70/134 SYR4 2012–2018
Bromoform
27.14 µg/L
No EPA limit set
worst single sample: 45.7 µg/L
47/80 SYR4 2012–2019
TTHM
76.565 µg/L 96%
of the EPA limit 80 µg/L
worst single sample: 99.2 µg/L
24/24 SYR4 2012–2019
Dichloroacetic Acid
9.675 µg/L
No EPA limit set
worst single sample: 12.8 µg/L
22/24 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
27.995 µg/L 47%
of the EPA limit 60 µg/L
worst single sample: 31.3 µg/L
22/24 SYR4 2012–2019
Trichloroacetic Acid
11.1 µg/L
No EPA limit set
worst single sample: 12.5 µg/L
21/24 SYR4 2012–2019
Barium
74.6 µg/L 3.7%
of the EPA limit 2000 µg/L
worst single sample: 80 µg/L
19/19 SYR4 2012–2019
Fluoride
575.7 µg/L 14%
of the EPA limit 4000 µg/L
worst single sample: 717 µg/L
19/19 SYR4 2012–2019
Nitrate-Nitrite
71.65 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 100 µg/L
19/23 SYR4 2012–2019
Dibromoacetic Acid
10.74 µg/L
No EPA limit set
worst single sample: 12.5 µg/L
17/24 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Xylenes, Total
92.935 µg/L 0.9%
of the EPA limit 10000 µg/L
worst single sample: 163 µg/L
10/56 SYR4 2012–2019
Lithium
15 µg/L
No EPA limit set
10/18 UCMR-5 2023
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
9/9 SYR4 2012–2018
Monochloroacetic Acid
9.38 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
9/24 SYR4 2012–2019
Chromium
3.6 µg/L 3.6%
of the EPA limit 100 µg/L
worst single sample: 4.2 µg/L
7/19 SYR4 2012–2019
Ethylbenzene
16.651 µg/L 2.4%
of the EPA limit 700 µg/L
worst single sample: 18.4 µg/L
3/56 SYR4 2012–2019
Monobromoacetic Acid
1.28 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
3/24 SYR4 2012–2019
Toluene
2.933 µg/L 0.3%
of the EPA limit 1000 µg/L
worst single sample: 3.01 µg/L
3/56 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.6 µg/L 27%
of the EPA limit 6 µg/L
1/63 SYR4 2012–2019
Gross Beta Particle Activity
4.2 pCi/L
No EPA limit set
1/11 SYR4 2012–2019
Nitrite
70.8 µg/L 7.1%
of the EPA limit 1000 µg/L
1/25 SYR4 2012–2019
Selenium
2.5 µg/L 5%
of the EPA limit 50 µg/L
1/19 SYR4 2012–2019
Thallium, Total
0.2410 µg/L 12%
of the EPA limit 2 µg/L
1/19 SYR4 2012–2019
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GRAMBEL, ERIC
Phone
903-342-3525

Frequently asked questions about Sharon Wsc

Is Sharon Wsc tap water safe to drink?

EPA monitoring detected 29 contaminants in Sharon Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sharon Wsc's water?

EPA monitoring detected Nitrate, Copper, Chloroform, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Sharon Wsc serve?

Sharon Wsc reports serving 9,111 people in Texas, per its EPA record.

Has Sharon Wsc had any water quality violations?

The EPA has 23 violations on file for Sharon Wsc, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.