← Arizona

Tap water quality report

Holly Lake Ranch

EPA monitoring tested this supplier for 109 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
25
detected
3,540
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Wood

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
38
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2021-01-01 → 2023-12-31
MR Monitoring Resolved 2017-11-08
MR Monitoring Resolved 2017-11-08
MR Monitoring Resolved 2017-11-08
MR Monitoring Resolved 2017-11-08
MR Monitoring Resolved 2017-01-01 → 2017-06-30
MR Monitoring Resolved 2017-01-01 → 2017-06-30
MR Monitoring Resolved 2017-01-01 → 2017-06-30
MR Monitoring Resolved 2017-01-01 → 2017-06-30
MR Monitoring Resolved 2017-01-01 → 2017-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
529 µg/L 41%
of the EPA limit 1300 µg/L
worst single sample: 761 µg/L
132/133 SYR4 2013–2017
Lead
4.808 µg/L 32%
of the EPA limit 15 µg/L
worst single sample: 66.9 µg/L
107/133 SYR4 2013–2017
Nitrate
104 µg/L 1%
of the EPA limit 10000 µg/L
worst single sample: 190 µg/L
90/112 SYR4 2012–2019
Chloroform
34.62 µg/L
No EPA limit set
worst single sample: 45.8 µg/L
87/88 SYR4 2012–2019
Bromodichloromethane
26.94 µg/L
No EPA limit set
worst single sample: 42.06 µg/L
85/88 SYR4 2012–2019
Dibromochloromethane
24.12 µg/L
No EPA limit set
worst single sample: 36.88 µg/L
85/88 SYR4 2012–2019
Dichloroacetic Acid
12.85 µg/L
No EPA limit set
worst single sample: 15.2 µg/L
44/44 SYR4 2012–2019
TTHM
84.315 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 113 µg/L
44/44 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
24.07 µg/L 40%
of the EPA limit 60 µg/L
worst single sample: 40.1 µg/L
44/44 SYR4 2012–2019
Trichloroacetic Acid
9 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
39/44 SYR4 2012–2019
Bromoform
9.787 µg/L
No EPA limit set
worst single sample: 12.2 µg/L
34/88 SYR4 2012–2019
Dibromoacetic Acid
7.115 µg/L
No EPA limit set
worst single sample: 8 µg/L
34/44 SYR4 2012–2019
Fluoride
329.2 µg/L 8.2%
of the EPA limit 4000 µg/L
worst single sample: 500 µg/L
15/15 SYR4 2013–2019
Barium
68.165 µg/L 3.4%
of the EPA limit 2000 µg/L
worst single sample: 72 µg/L
14/14 SYR4 2014–2019
Nitrate-Nitrite
68.25 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 104 µg/L
14/21 SYR4 2012–2015
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Chromium
3.83 µg/L 3.8%
of the EPA limit 100 µg/L
worst single sample: 4.6 µg/L
12/14 SYR4 2014–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
6/6 SYR4 2015
Monochloroacetic Acid
5.625 µg/L
No EPA limit set
worst single sample: 6.8 µg/L
6/44 SYR4 2012–2019
Xylenes, Total
6.342 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 7.02 µg/L
4/44 SYR4 2013–2019
Cyanide
24 µg/L 12%
of the EPA limit 200 µg/L
1/14 SYR4 2014–2017
Ethylbenzene
1.13 µg/L 0.2%
of the EPA limit 700 µg/L
1/44 SYR4 2013–2019
Gross Beta Particle Activity
4.9 pCi/L
No EPA limit set
1/7 SYR4 2015–2017
Monobromoacetic Acid
4.7 µg/L
No EPA limit set
1/44 SYR4 2012–2019
Lithium
9.1 µg/L
No EPA limit set
1/10 UCMR-5 2023
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
THOMPSON, MOSES
Phone
623-298-3753

Frequently asked questions about Holly Lake Ranch

Is Holly Lake Ranch tap water safe to drink?

EPA monitoring detected 25 contaminants in Holly Lake Ranch's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Holly Lake Ranch's water?

EPA monitoring detected Copper, Lead, Nitrate, Chloroform, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Holly Lake Ranch serve?

Holly Lake Ranch reports serving 3,540 people in Arizona, per its EPA record.

Has Holly Lake Ranch had any water quality violations?

The EPA has 38 violations on file for Holly Lake Ranch, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.