Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| RPT | Monitoring | Unaddressed | 2025-07-02 |
| MR | Monitoring | Resolved | 2019-10-01 |
| MR | Monitoring | Resolved | 2019-10-01 |
| MR | Monitoring | Resolved | 2019-10-01 |
| MR | Monitoring | Resolved | 2019-10-01 |
| Other | Monitoring | Resolved | 2016-07-01 |
| Other | Monitoring | Resolved | 2016-07-01 |
| MR | Monitoring | Resolved | 2010-07-01 → 2010-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 71.75 µg/L 0.7% of the EPA limit 10000 µg/L
worst single sample: 119 µg/L | 36/46 | SYR4 | 2012–2019 |
| Copper | 506.7 µg/L 39% of the EPA limit 1300 µg/L
worst single sample: 918 µg/L | 34/35 | SYR4 | 2012–2019 |
| Lead | 1.7875 µg/L 12% of the EPA limit 15 µg/L
worst single sample: 3.13 µg/L | 16/35 | SYR4 | 2012–2019 |
| Bromodichloromethane | 8.835 µg/L No EPA limit set
worst single sample: 9.15 µg/L | 15/20 | SYR4 | 2012–2019 |
| Dibromochloromethane | 16.75 µg/L No EPA limit set
worst single sample: 17.1 µg/L | 15/20 | SYR4 | 2012–2019 |
| Chloroform | 5.7295 µg/L No EPA limit set
worst single sample: 5.97 µg/L | 14/20 | SYR4 | 2012–2019 |
| Bromoform | 23.45 µg/L No EPA limit set
worst single sample: 24.9 µg/L | 11/20 | SYR4 | 2012–2019 |
| Fluoride | 500.4 µg/L 13% of the EPA limit 4000 µg/L
worst single sample: 510 µg/L | 9/9 | SYR4 | 2012–2018 |
| Barium | 76.195 µg/L 3.8% of the EPA limit 2000 µg/L
worst single sample: 76.3 µg/L | 8/8 | SYR4 | 2012–2019 |
| TTHM | 52.35 µg/L 65% of the EPA limit 80 µg/L
worst single sample: 53.4 µg/L | 8/8 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 14.49 µg/L 24% of the EPA limit 60 µg/L
worst single sample: 14.7 µg/L | 8/8 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 52.49 µg/L 0.5% of the EPA limit 10000 µg/L
worst single sample: 56 µg/L | 7/7 | SYR4 | 2013–2019 |
| Chromium | 2.075 µg/L 2.1% of the EPA limit 100 µg/L
worst single sample: 2.2 µg/L | 6/8 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 2.125 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 6/8 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2023 |
| Dibromoacetic Acid | 5.48 µg/L No EPA limit set
worst single sample: 5.6 µg/L | 5/8 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 4/4 | SYR4 | 2012–2018 |
| Trichloroacetic Acid | 2.25 µg/L No EPA limit set
worst single sample: 2.4 µg/L | 4/8 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 6.235 pCi/L No EPA limit set
worst single sample: 6.3 pCi/L | 2/7 | SYR4 | 2012–2018 |
| Monochloroacetic Acid | 10.435 µg/L No EPA limit set
worst single sample: 10.6 µg/L | 2/8 | SYR4 | 2013–2019 |
| Arsenic | 0.2990 µg/L 3% of the EPA limit 10 µg/L | 1/8 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 0.6000 µg/L 10% of the EPA limit 6 µg/L | 1/11 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.2 µg/L No EPA limit set | 1/8 | SYR4 | 2013–2019 |
| Selenium | 0.9120 µg/L 1.8% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2012–2019 |
55 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Alba
Is City of Alba tap water safe to drink?
EPA monitoring detected 24 contaminants in City of Alba's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Alba's water?
EPA monitoring detected Nitrate, Copper, Lead, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does City of Alba serve?
City of Alba reports serving 504 people in Texas, per its EPA record.
Has City of Alba had any water quality violations?
The EPA has 8 violations on file for City of Alba, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.