← Texas

Tap water quality report

City of Winnsboro

EPA monitoring tested this supplier for 108 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
23
detected
3,614
people served
30
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Wood

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

30
health-based violations
55
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-04-01
TT Health-based Resolved 2021-03-31
TT Health-based Resolved 2021-03-31
TT Health-based Resolved 2021-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
175.25 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 1200 µg/L
96/105 SYR4 2012–2019
Lead
34.71 µg/L 231%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 286 µg/L
75/105 SYR4 2012–2019
Bromodichloromethane
15.315 µg/L
No EPA limit set
worst single sample: 16.7 µg/L
60/60 SYR4 2012–2019
Chloroform
42.335 µg/L
No EPA limit set
worst single sample: 51.1 µg/L
60/60 SYR4 2012–2019
Dibromochloromethane
5.18 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
55/60 SYR4 2012–2019
TTHM
52.46 µg/L 66%
of the EPA limit 80 µg/L
worst single sample: 67.2 µg/L
52/53 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
33.15 µg/L 55%
of the EPA limit 60 µg/L
worst single sample: 45 µg/L
52/52 SYR4 2012–2019
Dichloroacetic Acid
21.14 µg/L
No EPA limit set
worst single sample: 24.6 µg/L
50/52 SYR4 2012–2019
Trichloroacetic Acid
10.72 µg/L
No EPA limit set
worst single sample: 12.1 µg/L
49/52 SYR4 2012–2019
Monochloroacetic Acid
4.97 µg/L
No EPA limit set
worst single sample: 14.9 µg/L
23/52 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2023
Nitrate
867 µg/L 8.7%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Dibromoacetic Acid
1.56 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
8/52 SYR4 2012–2019
Fluoride
127.3 µg/L 3.2%
of the EPA limit 4000 µg/L
worst single sample: 142 µg/L
8/8 SYR4 2012–2019
Barium
48.8 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 50 µg/L
7/7 SYR4 2013–2019
Atrazine
0.1000 µg/L 3.3%
of the EPA limit 3 µg/L
2/8 SYR4 2012–2019
Cyanide
72.66 µg/L 36%
of the EPA limit 200 µg/L
worst single sample: 73 µg/L
2/6 SYR4 2014–2019
Chromium
2.4905 µg/L 2.5%
of the EPA limit 100 µg/L
worst single sample: 2.6 µg/L
2/7 SYR4 2013–2019
Arsenic
0.9600 µg/L 9.6%
of the EPA limit 10 µg/L
1/7 SYR4 2013–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
Gross Beta Particle Activity
6.4 pCi/L
No EPA limit set
1/1 SYR4 2015
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
1/52 SYR4 2012–2019
Selenium
3 µg/L 6%
of the EPA limit 50 µg/L
1/7 SYR4 2013–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PARRISH, RICHARD, RANDY
Phone
903-342-3654
Email
RPARRISH@WINNSBOROTEXAS.COM

Frequently asked questions about City of Winnsboro

Is City of Winnsboro tap water safe to drink?

EPA monitoring detected 23 contaminants in City of Winnsboro's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Winnsboro's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does City of Winnsboro serve?

City of Winnsboro reports serving 3,614 people in Texas, per its EPA record.

Has City of Winnsboro had any water quality violations?

The EPA has 55 violations on file for City of Winnsboro, of which 30 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.