← Texas

Tap water quality report

City of Decatur Water Plant

EPA monitoring tested this supplier for 108 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
25
detected
6,910
people served
68
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Wise

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

68
health-based violations
87
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-05-01 → 2025-05-31
MCL Health-based Resolved 2025-05-01 → 2025-05-31
MCL Health-based Resolved 2025-05-01 → 2025-05-31
MCL Health-based Resolved 2025-05-01 → 2025-05-31
MCL Health-based Resolved 2025-05-01 → 2025-05-31
TT Health-based Resolved 2021-04-01 → 2021-04-30
TT Health-based Resolved 2021-04-01 → 2021-04-30
TT Health-based Resolved 2021-04-01 → 2021-04-30
TT Health-based Resolved 2021-04-01 → 2021-04-30
MCL Health-based Resolved 2016-04-01 → 2016-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0080 µg/L 3/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
27.825 µg/L
No EPA limit set
worst single sample: 29.4 µg/L
68/68 SYR4 2012–2019
Chloroform
78.72 µg/L
No EPA limit set
worst single sample: 141 µg/L
68/68 SYR4 2012–2019
Dibromochloromethane
17.93 µg/L
No EPA limit set
worst single sample: 19.6 µg/L
68/68 SYR4 2012–2019
TTHM
113 µg/L 141%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 172 µg/L
57/59 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
67.76 µg/L 113%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 99.7 µg/L
57/57 SYR4 2012–2019
Trichloroacetic Acid
33.2 µg/L
No EPA limit set
worst single sample: 40.6 µg/L
57/57 SYR4 2012–2019
Dichloroacetic Acid
33.38 µg/L
No EPA limit set
worst single sample: 46.8 µg/L
55/57 SYR4 2012–2019
Copper
111.15 µg/L 8.6%
of the EPA limit 1300 µg/L
worst single sample: 180 µg/L
54/65 SYR4 2013–2019
Bromoform
4.275 µg/L
No EPA limit set
worst single sample: 5.4 µg/L
46/68 SYR4 2012–2019
Dibromoacetic Acid
5.69 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
42/57 SYR4 2012–2019
Nitrate
248 µg/L 2.5%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Monochloroacetic Acid
15.1 µg/L
No EPA limit set
worst single sample: 27.5 µg/L
17/57 SYR4 2012–2019
Lead
5.6325 µg/L 38%
of the EPA limit 15 µg/L
worst single sample: 7.5 µg/L
16/65 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Fluoride
226.95 µg/L 5.7%
of the EPA limit 4000 µg/L
worst single sample: 228 µg/L
8/8 SYR4 2012–2019
Monobromoacetic Acid
2.43 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
8/57 SYR4 2012–2019
Barium
69.67 µg/L 3.5%
of the EPA limit 2000 µg/L
worst single sample: 73 µg/L
7/7 SYR4 2013–2019
Cyanide
111.72 µg/L 56%
of the EPA limit 200 µg/L
worst single sample: 117 µg/L
4/6 SYR4 2014–2019
Chromium
3.206 µg/L 3.2%
of the EPA limit 100 µg/L
worst single sample: 3.33 µg/L
3/7 SYR4 2013–2019
Arsenic
0.9815 µg/L 9.8%
of the EPA limit 10 µg/L
worst single sample: 0.9900 µg/L
2/7 SYR4 2013–2019
Antimony, Total
0.2100 µg/L 3.5%
of the EPA limit 6 µg/L
1/7 SYR4 2013–2019
Carbon Tetrachloride
0.7500 µg/L 15%
of the EPA limit 5 µg/L
1/11 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Gross Beta Particle Activity
4.7 pCi/L
No EPA limit set
1/1 SYR4 2016
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCQUISTON, MIKE
Phone
940-393-0200

Frequently asked questions about City of Decatur Water Plant

Is City of Decatur Water Plant tap water safe to drink?

EPA monitoring detected 25 contaminants in City of Decatur Water Plant's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Decatur Water Plant's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Decatur Water Plant serve?

City of Decatur Water Plant reports serving 6,910 people in Texas, per its EPA record.

Has City of Decatur Water Plant had any water quality violations?

The EPA has 87 violations on file for City of Decatur Water Plant, of which 68 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.