Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2025-12-30 |
| MR | Monitoring | Resolved | 2025-12-30 |
| MR | Monitoring | Resolved | 2016-09-29 |
| MR | Monitoring | Resolved | 2016-09-29 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 530 µg/L 41% of the EPA limit 1300 µg/L | 53/54 | SYR4 | 2012–2019 |
| Nitrate | 30 µg/L 0.3% of the EPA limit 10000 µg/L | 24/32 | SYR4 | 2012–2019 |
| Dibromochloromethane | 4.8 µg/L No EPA limit set | 16/18 | SYR4 | 2013–2019 |
| Bromoform | 4.6 µg/L No EPA limit set | 13/18 | SYR4 | 2013–2019 |
| Bromodichloromethane | 2.4 µg/L No EPA limit set | 9/18 | SYR4 | 2013–2019 |
| TTHM | 12.8 µg/L 16% of the EPA limit 80 µg/L | 8/8 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2025 |
| Lead | 6.9 µg/L 46% of the EPA limit 15 µg/L | 7/54 | SYR4 | 2012–2019 |
| Barium | 189 µg/L 9.5% of the EPA limit 2000 µg/L | 6/6 | SYR4 | 2012–2018 |
| Di(2-ethylhexyl) Phthalate | 6.3 µg/L 105% of the EPA limit, in the worst sample — 6 µg/L | 6/17 | SYR4 | 2016–2019 |
| Fluoride | 520 µg/L 13% of the EPA limit 4000 µg/L | 6/6 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 3.9 pCi/L 78% of the EPA limit 5 pCi/L | 4/4 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1.8 µg/L No EPA limit set | 4/8 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 12.3 pCi/L No EPA limit set | 4/4 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 30 µg/L 0.3% of the EPA limit 10000 µg/L | 4/6 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 2.9 µg/L 4.8% of the EPA limit 60 µg/L | 4/8 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 6.7 pCi/L 45% of the EPA limit 15 pCi/L | 3/3 | SYR4 | 2015–2019 |
| Chloroform | 1.1 µg/L No EPA limit set | 2/18 | SYR4 | 2013–2019 |
| Xylenes, Total | 1.9 µg/L 0% of the EPA limit 10000 µg/L | 2/10 | SYR4 | 2015–2019 |
| Dichloroacetic Acid | 1.1 µg/L No EPA limit set | 1/8 | SYR4 | 2013–2019 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about Three Oaks Wsc
Is Three Oaks Wsc tap water safe to drink?
EPA monitoring detected 20 contaminants in Three Oaks Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Three Oaks Wsc's water?
EPA monitoring detected Copper, Nitrate, Dibromochloromethane, Bromoform, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Three Oaks Wsc serve?
Three Oaks Wsc reports serving 2,007 people in Texas, per its EPA record.
Has Three Oaks Wsc had any water quality violations?
The EPA has 4 violations on file for Three Oaks Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.