Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2026-01-01 → 2026-03-31 |
| MCL | Health-based | Archived | 2026-01-01 → 2026-03-31 |
| MCL | Health-based | Archived | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Archived | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Archived | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Archived | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Archived | 2025-04-01 → 2025-06-30 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 662 µg/L 51% of the EPA limit 1300 µg/L | 84/84 | SYR4 | 2013–2019 |
| Bromodichloromethane | 44.6 µg/L No EPA limit set | 65/65 | SYR4 | 2012–2019 |
| Bromoform | 8.5 µg/L No EPA limit set | 65/65 | SYR4 | 2012–2019 |
| Chloroform | 46.7 µg/L No EPA limit set | 65/65 | SYR4 | 2012–2019 |
| Dibromochloromethane | 30.9 µg/L No EPA limit set | 65/65 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 33.7 µg/L No EPA limit set | 57/57 | SYR4 | 2012–2019 |
| TTHM | 126 µg/L 158% of the EPA limit, in the worst sample — 80 µg/L | 57/57 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 63.4 µg/L 106% of the EPA limit, in the worst sample — 60 µg/L | 57/57 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 22.8 µg/L No EPA limit set | 57/57 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 10.8 µg/L No EPA limit set | 56/57 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.5 µg/L No EPA limit set | 16/57 | SYR4 | 2012–2019 |
| Nitrate | 740 µg/L 7.4% of the EPA limit 10000 µg/L | 16/18 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2023 |
| Lead | 8.1 µg/L 54% of the EPA limit 15 µg/L | 9/85 | SYR4 | 2013–2019 |
| Fluoride | 700 µg/L 18% of the EPA limit 4000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Barium | 88.4 µg/L 4.4% of the EPA limit 2000 µg/L | 7/7 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 8.2 µg/L No EPA limit set | 4/57 | SYR4 | 2012–2019 |
| Lithium | 40.7 µg/L No EPA limit set | 4/4 | UCMR-5 | 2025 |
| Cyanide | 60 µg/L 30% of the EPA limit 200 µg/L | 2/8 | SYR4 | 2012–2019 |
| Dalapon | 1.2 µg/L 0.6% of the EPA limit 200 µg/L | 2/57 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 1.4 µg/L 23% of the EPA limit 6 µg/L | 1/8 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 4.9 pCi/L No EPA limit set | 1/1 | SYR4 | 2016 |
| Selenium | 3.6 µg/L 7.2% of the EPA limit 50 µg/L | 1/7 | SYR4 | 2013–2019 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Webb County Water Utilities
Is Webb County Water Utilities tap water safe to drink?
EPA monitoring detected 25 contaminants in Webb County Water Utilities's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Webb County Water Utilities's water?
EPA monitoring detected Copper, Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Webb County Water Utilities serve?
Webb County Water Utilities reports serving 8,358 people in Texas, per its EPA record.
Has Webb County Water Utilities had any water quality violations?
The EPA has 754 violations on file for Webb County Water Utilities, of which 363 are health-based (a contaminant limit or required treatment was breached) and 8 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.