← Texas

Tap water quality report

Fruitvale Wsc

EPA monitoring tested this supplier for 109 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
26
detected
3,747
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Van Zandt

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2014-04-01 → 2014-06-30
MR Monitoring Resolved 2014-04-01 → 2014-06-30
MR Monitoring Resolved 2014-04-01 → 2014-06-30
MR Monitoring Resolved 2014-04-01 → 2014-06-30
MR Monitoring Resolved 2013-05-01 → 2013-05-31
MR Monitoring Resolved 2013-05-01 → 2013-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
408 µg/L 4.1%
of the EPA limit 10000 µg/L
worst single sample: 445 µg/L
52/64 SYR4 2012–2019
Copper
280 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 450 µg/L
48/48 SYR4 2014–2017
Bromodichloromethane
23.875 µg/L
No EPA limit set
worst single sample: 30.5 µg/L
46/47 SYR4 2014–2019
Dibromochloromethane
36.15 µg/L
No EPA limit set
worst single sample: 39.4 µg/L
46/47 SYR4 2014–2019
Chloroform
10.8 µg/L
No EPA limit set
worst single sample: 16.3 µg/L
45/47 SYR4 2014–2019
Bromoform
25.065 µg/L
No EPA limit set
worst single sample: 35.6 µg/L
44/47 SYR4 2014–2019
TTHM
89.125 µg/L 111%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 96.6 µg/L
26/26 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
19.475 µg/L 32%
of the EPA limit 60 µg/L
worst single sample: 26 µg/L
26/26 SYR4 2014–2019
Dibromoacetic Acid
8.225 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
24/26 SYR4 2014–2019
Dichloroacetic Acid
5.09 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
23/26 SYR4 2014–2019
Lead
3.8 µg/L 25%
of the EPA limit 15 µg/L
worst single sample: 4.5 µg/L
21/48 SYR4 2014–2017
Trichloroacetic Acid
3.58 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
19/26 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Nitrate-Nitrite
339 µg/L 3.4%
of the EPA limit 10000 µg/L
worst single sample: 445 µg/L
9/12 SYR4 2012–2015
Barium
49.015 µg/L 2.5%
of the EPA limit 2000 µg/L
worst single sample: 50.1 µg/L
8/8 SYR4 2014–2017
Chromium
3.53 µg/L 3.5%
of the EPA limit 100 µg/L
worst single sample: 3.6 µg/L
8/8 SYR4 2014–2017
Fluoride
184.95 µg/L 4.6%
of the EPA limit 4000 µg/L
worst single sample: 186 µg/L
8/8 SYR4 2014–2017
Xylenes, Total
10.799 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 11.8 µg/L
8/21 SYR4 2014–2019
Monobromoacetic Acid
1.34 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
7/26 SYR4 2014–2019
Monochloroacetic Acid
10.15 µg/L
No EPA limit set
worst single sample: 10.6 µg/L
7/26 SYR4 2014–2019
Lithium
12.8 µg/L
No EPA limit set
7/8 UCMR-5 2024
Ethylbenzene
1.82 µg/L 0.3%
of the EPA limit 700 µg/L
worst single sample: 2 µg/L
6/21 SYR4 2014–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2015
Cyanide
5.13 µg/L 2.6%
of the EPA limit 200 µg/L
1/8 SYR4 2014–2017
Di(2-ethylhexyl) Phthalate
1.7 µg/L 28%
of the EPA limit 6 µg/L
1/24 SYR4 2014–2019
Mercury
0.0880 µg/L 4.4%
of the EPA limit 2 µg/L
1/8 SYR4 2014–2017
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, DALE
Phone
903-896-1884

Frequently asked questions about Fruitvale Wsc

Is Fruitvale Wsc tap water safe to drink?

EPA monitoring detected 26 contaminants in Fruitvale Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fruitvale Wsc's water?

EPA monitoring detected Nitrate, Copper, Bromodichloromethane, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Fruitvale Wsc serve?

Fruitvale Wsc reports serving 3,747 people in Texas, per its EPA record.

Has Fruitvale Wsc had any water quality violations?

The EPA has 16 violations on file for Fruitvale Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.