← Texas

Tap water quality report

Pritchett Water Supply Corporation

EPA monitoring tested this supplier for 109 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
26
detected
10,089
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Upshur

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2004-07-01 → 2004-07-31
MCL Health-based Resolved 2004-07-01 → 2004-07-31
MCL Health-based Resolved 2004-07-01 → 2004-07-31
MCL Health-based Resolved 2004-07-01 → 2004-07-31
Other Monitoring Resolved 2022-03-24
Other Monitoring Resolved 2022-03-24
Other Monitoring Resolved 2022-03-21
Other Monitoring Resolved 2022-03-21
MR Monitoring Resolved 2021-01-01
MR Monitoring Resolved 2021-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
319.75 µg/L 3.2%
of the EPA limit 10000 µg/L
worst single sample: 660 µg/L
186/206 SYR4 2012–2019
Bromodichloromethane
15.2725 µg/L
No EPA limit set
worst single sample: 34 µg/L
120/121 SYR4 2012–2019
Chloroform
10.3445 µg/L
No EPA limit set
worst single sample: 14 µg/L
120/121 SYR4 2012–2019
Dibromochloromethane
31.73 µg/L
No EPA limit set
worst single sample: 51.2 µg/L
120/121 SYR4 2012–2019
Copper
407 µg/L 31%
of the EPA limit 1300 µg/L
worst single sample: 690 µg/L
82/86 SYR4 2013–2017
Bromoform
24.99 µg/L
No EPA limit set
worst single sample: 44.5 µg/L
60/121 SYR4 2012–2019
TTHM
52.235 µg/L 65%
of the EPA limit 80 µg/L
worst single sample: 114 µg/L
44/45 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
19.97 µg/L 33%
of the EPA limit 60 µg/L
worst single sample: 22.4 µg/L
43/44 SYR4 2013–2019
Dichloroacetic Acid
3.5 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
41/44 SYR4 2013–2019
Trichloroacetic Acid
2.94 µg/L
No EPA limit set
worst single sample: 4 µg/L
39/44 SYR4 2013–2019
Dibromoacetic Acid
14.72 µg/L
No EPA limit set
worst single sample: 15.1 µg/L
30/44 SYR4 2013–2019
Barium
74.4 µg/L 3.7%
of the EPA limit 2000 µg/L
worst single sample: 150 µg/L
29/29 SYR4 2013–2019
Fluoride
333.6 µg/L 8.3%
of the EPA limit 4000 µg/L
worst single sample: 535 µg/L
29/29 SYR4 2013–2019
Lead
12.55 µg/L 84%
of the EPA limit 15 µg/L
worst single sample: 44 µg/L
24/86 SYR4 2013–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Nitrate-Nitrite
343.1 µg/L 3.4%
of the EPA limit 10000 µg/L
worst single sample: 649 µg/L
20/30 SYR4 2012–2015
Chromium
6.27 µg/L 6.3%
of the EPA limit 100 µg/L
worst single sample: 15.3 µg/L
15/29 SYR4 2013–2019
Xylenes, Total
12.4 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 20.1 µg/L
12/77 SYR4 2012–2019
Lithium
16.5 µg/L
No EPA limit set
12/26 UCMR-5 2024
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
11/11 SYR4 2013–2019
Monobromoacetic Acid
1.675 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
6/44 SYR4 2013–2019
Selenium
2.256 µg/L 4.5%
of the EPA limit 50 µg/L
worst single sample: 2.42 µg/L
5/29 SYR4 2013–2019
Ethylbenzene
1.543 µg/L 0.2%
of the EPA limit 700 µg/L
worst single sample: 1.59 µg/L
2/77 SYR4 2012–2019
2,4-D
0.1550 µg/L 0.2%
of the EPA limit 70 µg/L
1/32 SYR4 2013–2019
Arsenic
0.7200 µg/L 7.2%
of the EPA limit 10 µg/L
1/29 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/51 SYR4 2012–2019
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARS, JOSH
Phone
903-331-2858

Frequently asked questions about Pritchett Water Supply Corporation

Is Pritchett Water Supply Corporation tap water safe to drink?

EPA monitoring detected 26 contaminants in Pritchett Water Supply Corporation's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pritchett Water Supply Corporation's water?

EPA monitoring detected Nitrate, Bromodichloromethane, Chloroform, Dibromochloromethane, Copper, and others. The full list with the level and data source for each is above.

How many people does Pritchett Water Supply Corporation serve?

Pritchett Water Supply Corporation reports serving 10,089 people in Texas, per its EPA record.

Has Pritchett Water Supply Corporation had any water quality violations?

The EPA has 21 violations on file for Pritchett Water Supply Corporation, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.