Tap water quality report

Bear Creek Park

EPA monitoring tested this supplier for 78 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
20
detected
270
people served
11
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
Travis

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

11
health-based violations
193
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2025-12-01 → 2025-12-31
TT Health-based Resolved 2025-12-01 → 2025-12-31
TT Health-based Resolved 2025-12-01 → 2025-12-31
TT Health-based Resolved 2014-07-01 → 2014-07-31
TT Health-based Resolved 2014-07-01 → 2014-07-31
TT Health-based Resolved 2014-07-01 → 2014-07-31
TT Health-based Resolved 2014-06-01 → 2014-06-30
TT Health-based Resolved 2014-06-01 → 2014-06-30
TT Health-based Resolved 2014-06-01 → 2014-06-30
TT Health-based Resolved 2014-06-01 → 2014-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1947 µg/L 19%
of the EPA limit 10000 µg/L
worst single sample: 1980 µg/L
32/32 SYR4 2012–2019
Copper
132.95 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 141 µg/L
22/23 SYR4 2013–2019
Dibromochloromethane
24 µg/L
No EPA limit set
19/22 SYR4 2012–2019
Bromoform
5.745 µg/L
No EPA limit set
worst single sample: 7.5 µg/L
14/22 SYR4 2012–2019
Barium
128.8 µg/L 6.4%
of the EPA limit 2000 µg/L
worst single sample: 166 µg/L
13/13 SYR4 2013–2019
Bromodichloromethane
30.6 µg/L
No EPA limit set
worst single sample: 33 µg/L
13/22 SYR4 2012–2019
Fluoride
234 µg/L 5.9%
of the EPA limit 4000 µg/L
worst single sample: 240 µg/L
13/14 SYR4 2012–2019
Chloroform
40.6 µg/L
No EPA limit set
worst single sample: 45 µg/L
9/22 SYR4 2012–2019
TTHM
13.2 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 16.5 µg/L
7/9 SYR4 2012–2019
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
5/5 LCR 2024
Lead
1.68 µg/L 11%
of the EPA limit 15 µg/L
worst single sample: 1.8 µg/L
5/23 SYR4 2013–2019
Dibromoacetic Acid
1.28 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
3/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.62 µg/L 7.7%
of the EPA limit 60 µg/L
worst single sample: 4.9 µg/L
3/8 SYR4 2012–2019
Xylenes, Total
1.17 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.2 µg/L
3/14 SYR4 2012–2019
2,4-D
0.2000 µg/L 0.3%
of the EPA limit 70 µg/L
2/10 SYR4 2012–2019
Dichloroacetic Acid
2.62 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
2/8 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
3.8 pCi/L 25%
of the EPA limit 15 pCi/L
1/3 SYR4 2014–2017
Nitrate-Nitrite
1510 µg/L 15%
of the EPA limit 10000 µg/L
1/1 SYR4 2019
Selenium
1.56 µg/L 3.1%
of the EPA limit 50 µg/L
1/13 SYR4 2013–2019
Trichloroacetic Acid
1.1 µg/L
No EPA limit set
1/8 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TPAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOLTZ, SCOT, W
Phone
512-990-4400
Email
swfoltz@aquaamerica.com

Frequently asked questions about Bear Creek Park

Is Bear Creek Park tap water safe to drink?

EPA monitoring detected 20 contaminants in Bear Creek Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bear Creek Park's water?

EPA monitoring detected Nitrate, Copper, Dibromochloromethane, Bromoform, Barium, and others. The full list with the level and data source for each is above.

How many people does Bear Creek Park serve?

Bear Creek Park reports serving 270 people in Texas, per its EPA record.

Has Bear Creek Park had any water quality violations?

The EPA has 193 violations on file for Bear Creek Park, of which 11 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.