← Texas

Tap water quality report

West Texas Boys Ranch

EPA monitoring tested this supplier for 79 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
20
detected
48
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Tom Green

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
230
violations on file
3
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1992-04-01 → 1992-04-30
MCL Health-based Archived 1992-04-01 → 1992-04-30
MON Monitoring Resolved 2026-04-01 → 2026-04-30
MON Monitoring Resolved 2026-04-01 → 2026-04-30
MON Monitoring Resolved 2026-04-01 → 2026-04-30
MR Monitoring Resolved 2024-12-30
MR Monitoring Resolved 2024-12-30
MON Monitoring Resolved 2024-12-01 → 2024-12-31
MON Monitoring Resolved 2024-12-01 → 2024-12-31
MON Monitoring Resolved 2024-12-01 → 2024-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1310 µg/L 13%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
129 µg/L 9.9%
of the EPA limit 1300 µg/L
worst single sample: 140 µg/L
12/12 SYR4 2013–2017
Bromoform
37.025 µg/L
No EPA limit set
worst single sample: 52.1 µg/L
10/10 SYR4 2012–2019
Dibromochloromethane
4.3 µg/L
No EPA limit set
7/10 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2024
Xylenes, Total
1.86 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 2 µg/L
5/7 SYR4 2015–2019
Arsenic
6.94 µg/L 69%
of the EPA limit 10 µg/L
worst single sample: 7.3 µg/L
3/3 SYR4 2013–2019
Barium
54.11 µg/L 2.7%
of the EPA limit 2000 µg/L
worst single sample: 55 µg/L
3/3 SYR4 2013–2019
Dibromoacetic Acid
9.33 µg/L
No EPA limit set
worst single sample: 9.6 µg/L
3/3 SYR4 2012–2019
Fluoride
882.3 µg/L 22%
of the EPA limit 4000 µg/L
worst single sample: 887 µg/L
3/3 SYR4 2013–2019
Nitrate-Nitrite
578 µg/L 5.8%
of the EPA limit 10000 µg/L
worst single sample: 600 µg/L
3/3 SYR4 2012–2015
TTHM
50.8 µg/L 64%
of the EPA limit 80 µg/L
worst single sample: 53.9 µg/L
3/3 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
10.32 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 10.7 µg/L
3/3 SYR4 2012–2019
Selenium
17.6945 µg/L 35%
of the EPA limit 50 µg/L
worst single sample: 18.4 µg/L
2/3 SYR4 2013–2019
Chromium
5.87 µg/L 5.9%
of the EPA limit 100 µg/L
1/3 SYR4 2013–2019
Combined Radium (-226 And -228)
3.7 pCi/L 74%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Combined Uranium
3.4 µg/L 11%
of the EPA limit 30 µg/L
1/1 SYR4 2016
Gross Alpha, Excl. Radon And U
1 pCi/L 6.7%
of the EPA limit 15 pCi/L
1/1 SYR4 2016
Lead
2.4 µg/L 16%
of the EPA limit 15 µg/L
1/12 SYR4 2013–2017
Monobromoacetic Acid
1.1 µg/L
No EPA limit set
1/3 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
VINCENT, JEREMY
Phone
325-949-1936

Frequently asked questions about West Texas Boys Ranch

Is West Texas Boys Ranch tap water safe to drink?

EPA monitoring detected 20 contaminants in West Texas Boys Ranch's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in West Texas Boys Ranch's water?

EPA monitoring detected Nitrate, Copper, Bromoform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does West Texas Boys Ranch serve?

West Texas Boys Ranch reports serving 48 people in Texas, per its EPA record.

Has West Texas Boys Ranch had any water quality violations?

The EPA has 230 violations on file for West Texas Boys Ranch, of which 2 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.