← Texas

Tap water quality report

City of Mount Pleasant

EPA monitoring tested this supplier for 107 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
25
detected
16,238
people served
8
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Titus

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2010-07-01 → 2010-07-31
MCL Health-based Resolved 2010-07-01 → 2010-07-31
MCL Health-based Resolved 2010-07-01 → 2010-07-31
RPT Monitoring Resolved 2025-07-02
Other Monitoring Resolved 2016-11-02

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0123 µg/L 2/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
24.535 µg/L
No EPA limit set
worst single sample: 40.6 µg/L
120/121 SYR4 2012–2019
Chloroform
40.695 µg/L
No EPA limit set
worst single sample: 76.7 µg/L
120/121 SYR4 2012–2019
Dibromochloromethane
16.23 µg/L
No EPA limit set
worst single sample: 18.5 µg/L
120/121 SYR4 2012–2019
Dichloroacetic Acid
24.475 µg/L
No EPA limit set
worst single sample: 38.3 µg/L
106/107 SYR4 2012–2019
TTHM
86.6 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 136 µg/L
106/108 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
43.875 µg/L 73%
of the EPA limit 60 µg/L
worst single sample: 71.6 µg/L
106/107 SYR4 2012–2019
Trichloroacetic Acid
12.575 µg/L
No EPA limit set
worst single sample: 18.3 µg/L
106/107 SYR4 2012–2019
Copper
99.21 µg/L 7.6%
of the EPA limit 1300 µg/L
worst single sample: 203 µg/L
80/95 SYR4 2013–2019
Dibromoacetic Acid
4.795 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
62/107 SYR4 2012–2019
Monochloroacetic Acid
4.995 µg/L
No EPA limit set
worst single sample: 15.2 µg/L
62/107 SYR4 2012–2019
Bromoform
2.8 µg/L
No EPA limit set
worst single sample: 32.1 µg/L
51/121 SYR4 2012–2019
Monobromoacetic Acid
3.125 µg/L
No EPA limit set
worst single sample: 3.6 µg/L
26/107 SYR4 2012–2019
Lead
3.0235 µg/L 20%
of the EPA limit 15 µg/L
worst single sample: 3.58 µg/L
24/95 SYR4 2013–2019
Nitrate
419.6 µg/L 4.2%
of the EPA limit 10000 µg/L
worst single sample: 422 µg/L
22/24 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Barium
71.2 µg/L 3.6%
of the EPA limit 2000 µg/L
worst single sample: 74 µg/L
8/8 SYR4 2013–2019
Fluoride
117.025 µg/L 2.9%
of the EPA limit 4000 µg/L
worst single sample: 127 µg/L
8/9 SYR4 2012–2019
Cyanide
86.08 µg/L 43%
of the EPA limit 200 µg/L
worst single sample: 89.4 µg/L
3/7 SYR4 2014–2019
Selenium
1.9085 µg/L 3.8%
of the EPA limit 50 µg/L
worst single sample: 1.93 µg/L
2/8 SYR4 2013–2019
Arsenic
0.7000 µg/L 7%
of the EPA limit 10 µg/L
1/8 SYR4 2013–2019
Gross Beta Particle Activity
4.6 pCi/L
No EPA limit set
1/2 SYR4 2017–2019
Nitrite
24.2 µg/L 2.4%
of the EPA limit 1000 µg/L
1/2 SYR4 2013–2019
Thallium, Total
0.3600 µg/L 18%
of the EPA limit 2 µg/L
1/8 SYR4 2013–2019
Xylenes, Total
0.5300 µg/L 0%
of the EPA limit 10000 µg/L
1/14 SYR4 2012–2019
82 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CRAIG, TRACY
Phone
903-575-8436
Email
mayor@mpcity.org

Frequently asked questions about City of Mount Pleasant

Is City of Mount Pleasant tap water safe to drink?

EPA monitoring detected 25 contaminants in City of Mount Pleasant's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Mount Pleasant's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does City of Mount Pleasant serve?

City of Mount Pleasant reports serving 16,238 people in Texas, per its EPA record.

Has City of Mount Pleasant had any water quality violations?

The EPA has 27 violations on file for City of Mount Pleasant, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.