← Texas

Tap water quality report

Tuscola-Taylor County Wcid 1

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
1,890
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Taylor

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
1
still open
ViolationTypeStatusPeriod
RPT Monitoring Unaddressed 2025-07-02
MR Monitoring Resolved 2016-07-01 → 2016-09-30
MR Monitoring Resolved 2016-07-01 → 2016-09-30
MR Monitoring Resolved 2016-07-01 → 2016-09-30
MR Monitoring Resolved 2016-07-01 → 2016-09-30
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
15.01 µg/L
No EPA limit set
worst single sample: 22 µg/L
54/54 SYR4 2012–2019
Bromoform
44.78 µg/L
No EPA limit set
worst single sample: 61.3 µg/L
54/54 SYR4 2012–2019
Dibromoacetic Acid
20.97 µg/L
No EPA limit set
worst single sample: 23.3 µg/L
54/54 SYR4 2012–2019
Dibromochloromethane
24.585 µg/L
No EPA limit set
worst single sample: 33.7 µg/L
54/54 SYR4 2012–2019
TTHM
72.875 µg/L 91%
of the EPA limit 80 µg/L
worst single sample: 87.3 µg/L
54/54 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
28.435 µg/L 47%
of the EPA limit 60 µg/L
worst single sample: 31.1 µg/L
54/54 SYR4 2012–2019
Dichloroacetic Acid
10.165 µg/L
No EPA limit set
worst single sample: 14.1 µg/L
50/54 SYR4 2012–2019
Chloroform
8.14 µg/L
No EPA limit set
worst single sample: 16.1 µg/L
27/54 SYR4 2012–2019
Monobromoacetic Acid
3.3 µg/L
No EPA limit set
worst single sample: 6 µg/L
25/54 SYR4 2012–2019
Copper
335.1 µg/L 26%
of the EPA limit 1300 µg/L
worst single sample: 390 µg/L
19/20 SYR4 2014–2017
Trichloroacetic Acid
4.19 µg/L
No EPA limit set
worst single sample: 5.1 µg/L
15/54 SYR4 2012–2019
Lead
5.27 µg/L 35%
of the EPA limit 15 µg/L
worst single sample: 5.9 µg/L
13/20 SYR4 2014–2017
Monochloroacetic Acid
4.16 µg/L
No EPA limit set
worst single sample: 4.6 µg/L
12/54 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
8/8 LCR 2023

Utility contact

Contact
SMITH, MATT
Phone
325-554-9443

Frequently asked questions about Tuscola-Taylor County Wcid 1

Is Tuscola-Taylor County Wcid 1 tap water safe to drink?

EPA monitoring detected 14 contaminants in Tuscola-Taylor County Wcid 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Tuscola-Taylor County Wcid 1's water?

EPA monitoring detected Bromodichloromethane, Bromoform, Dibromoacetic Acid, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Tuscola-Taylor County Wcid 1 serve?

Tuscola-Taylor County Wcid 1 reports serving 1,890 people in Texas, per its EPA record.

Has Tuscola-Taylor County Wcid 1 had any water quality violations?

The EPA has 7 violations on file for Tuscola-Taylor County Wcid 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.