← Texas

Tap water quality report

Chart House Condominium

EPA monitoring tested this supplier for 79 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
23
detected
75
people served
123
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Tarrant

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

123
health-based violations
355
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Uranium
33.1 µg/L 110%
of the EPA limit, in the worst sample — 30 µg/L
26/26 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
28 pCi/L 187%
of the EPA limit, in the worst sample — 15 pCi/L
26/26 SYR4 2012–2019
Gross Beta Particle Activity
130 pCi/L
No EPA limit set
22/26 SYR4 2012–2019
Combined Radium (-226 And -228)
8 pCi/L 160%
of the EPA limit, in the worst sample — 5 pCi/L
20/26 SYR4 2012–2019
Nitrate
740 µg/L 7.4%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
430 µg/L 33%
of the EPA limit 1300 µg/L
11/11 SYR4 2015–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Lead
4.6 µg/L 31%
of the EPA limit 15 µg/L
9/11 SYR4 2015–2018
Bromoform
8.79 µg/L
No EPA limit set
7/8 SYR4 2013–2019
Bromodichloromethane
42.1 µg/L
No EPA limit set
6/8 SYR4 2013–2019
Dibromochloromethane
24.3 µg/L
No EPA limit set
6/8 SYR4 2013–2019
Chloroform
32.3 µg/L
No EPA limit set
5/8 SYR4 2013–2019
Fluoride
249 µg/L 6.2%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Nitrate-Nitrite
715 µg/L 7.2%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2015
Barium
57 µg/L 2.9%
of the EPA limit 2000 µg/L
2/2 SYR4 2015–2018
Dibromoacetic Acid
3.3 µg/L
No EPA limit set
2/3 SYR4 2013–2019
TTHM
14.4 µg/L 18%
of the EPA limit 80 µg/L
2/3 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
6.7 µg/L 11%
of the EPA limit 60 µg/L
2/3 SYR4 2013–2019
Arsenic
0.7500 µg/L 7.5%
of the EPA limit 10 µg/L
1/2 SYR4 2015–2018
Chromium
2.2 µg/L 2.2%
of the EPA limit 100 µg/L
1/2 SYR4 2015–2018
Dichloroacetic Acid
2.1 µg/L
No EPA limit set
1/3 SYR4 2013–2019
Selenium
3 µg/L 6%
of the EPA limit 50 µg/L
1/2 SYR4 2015–2018
Trichloroacetic Acid
1.3 µg/L
No EPA limit set
1/3 SYR4 2013–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HARRIS, DAN
Phone
469-697-7666

Frequently asked questions about Chart House Condominium

Is Chart House Condominium tap water safe to drink?

EPA monitoring detected 23 contaminants in Chart House Condominium's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Chart House Condominium's water?

EPA monitoring detected Combined Uranium, Gross Alpha, Excl. Radon And U, Gross Beta Particle Activity, Combined Radium (-226 And -228), Nitrate, and others. The full list with the level and data source for each is above.

How many people does Chart House Condominium serve?

Chart House Condominium reports serving 75 people in Texas, per its EPA record.

Has Chart House Condominium had any water quality violations?

The EPA has 355 violations on file for Chart House Condominium, of which 123 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.