← Texas

Tap water quality report

City of River Oaks

EPA monitoring tested this supplier for 77 contaminants and detected 27. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
27
detected
7,691
people served
175
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Tarrant

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

175
health-based violations
210
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
607 µg/L 47%
of the EPA limit 1300 µg/L
worst single sample: 1210 µg/L
184/185 SYR4 2013–2019
Lead
6.255 µg/L 42%
of the EPA limit 15 µg/L
worst single sample: 19 µg/L
88/185 SYR4 2013–2019
Bromodichloromethane
44.84 µg/L
No EPA limit set
worst single sample: 50.5 µg/L
65/65 SYR4 2012–2019
Chloroform
91.46 µg/L
No EPA limit set
worst single sample: 197 µg/L
65/65 SYR4 2012–2019
Dibromochloromethane
20.99 µg/L
No EPA limit set
worst single sample: 26.4 µg/L
59/65 SYR4 2012–2019
Dichloroacetic Acid
54.46 µg/L
No EPA limit set
worst single sample: 83.5 µg/L
57/57 SYR4 2012–2019
TTHM
140.4 µg/L 176%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 258 µg/L
57/58 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
120.2 µg/L 200%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 158 µg/L
57/57 SYR4 2012–2019
Trichloroacetic Acid
52.85 µg/L
No EPA limit set
worst single sample: 73.1 µg/L
46/57 SYR4 2012–2019
Monochloroacetic Acid
15.275 µg/L
No EPA limit set
worst single sample: 24.6 µg/L
34/57 SYR4 2012–2019
Dibromoacetic Acid
6.05 µg/L
No EPA limit set
worst single sample: 6.3 µg/L
31/57 SYR4 2012–2019
Bromoform
3.438 µg/L
No EPA limit set
worst single sample: 4.34 µg/L
29/65 SYR4 2012–2019
Monobromoacetic Acid
2.94 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
24/57 SYR4 2012–2019
Lead
0.0015 mg/L 9.7%
of the EPA limit 0.0150 mg/L
20/20 LCR 2026
Nitrate
240 µg/L 2.4%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Fluoride
184.4 µg/L 4.6%
of the EPA limit 4000 µg/L
worst single sample: 204 µg/L
8/8 SYR4 2012–2019
Barium
91.2 µg/L 4.6%
of the EPA limit 2000 µg/L
worst single sample: 102 µg/L
7/7 SYR4 2013–2019
Cyanide
98.425 µg/L 49%
of the EPA limit 200 µg/L
worst single sample: 101 µg/L
6/6 SYR4 2014–2019
Chromium
3.868 µg/L 3.9%
of the EPA limit 100 µg/L
worst single sample: 4.26 µg/L
5/7 SYR4 2013–2019
Arsenic
1.4829 µg/L 15%
of the EPA limit 10 µg/L
worst single sample: 1.55 µg/L
3/7 SYR4 2013–2019
Atrazine
0.1000 µg/L 3.3%
of the EPA limit 3 µg/L
2/8 SYR4 2012–2019
Antimony, Total
0.2800 µg/L 4.7%
of the EPA limit 6 µg/L
1/7 SYR4 2013–2019
Gross Beta Particle Activity
4.6 pCi/L
No EPA limit set
1/1 SYR4 2016
Heptachlor Epoxide
0.0400 µg/L 20%
of the EPA limit 0.2000 µg/L
1/8 SYR4 2012–2019
Selenium
4.65 µg/L 9.3%
of the EPA limit 50 µg/L
1/7 SYR4 2013–2019
Simazine
0.0700 µg/L 1.8%
of the EPA limit 4 µg/L
1/8 SYR4 2012–2019
Thallium, Total
0.2250 µg/L 11%
of the EPA limit 2 µg/L
1/7 SYR4 2013–2019
50 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ASHTON, JOE
Phone
817-626-5421
Email
jashton@riveroakstx.com

Frequently asked questions about City of River Oaks

Is City of River Oaks tap water safe to drink?

EPA monitoring detected 27 contaminants in City of River Oaks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of River Oaks's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does City of River Oaks serve?

City of River Oaks reports serving 7,691 people in Texas, per its EPA record.

Has City of River Oaks had any water quality violations?

The EPA has 210 violations on file for City of River Oaks, of which 175 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.