← Texas

Tap water quality report

City of Hurst

EPA monitoring tested this supplier for 109 contaminants and detected 31. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
31
detected
40,454
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Tarrant

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MR Monitoring Resolved 2013-12-30
MR Monitoring Resolved 2013-12-30
MR Monitoring Resolved 2013-04-01 → 2013-06-30
MR Monitoring Resolved 2013-04-01 → 2013-06-30
MR Monitoring Resolved 2013-04-01 → 2013-06-30
MR Monitoring Resolved 2013-04-01 → 2013-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0063 µg/L 8/10 2024
Pfpea 0.0039 µg/L 7/10 2024
Pfhxa 0.0032 µg/L 4/10 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
5.89 µg/L
No EPA limit set
worst single sample: 11.1 µg/L
143/148 SYR4 2012–2019
Chloroform
13.19 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
143/148 SYR4 2012–2019
Dibromochloromethane
4.443 µg/L
No EPA limit set
worst single sample: 19.8 µg/L
139/148 SYR4 2012–2019
TTHM
20.6 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 25.7 µg/L
131/131 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.055 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 103 µg/L
130/131 SYR4 2012–2019
Dichloroacetic Acid
8.77 µg/L
No EPA limit set
worst single sample: 15.6 µg/L
124/131 SYR4 2012–2019
Copper
777.53 µg/L 60%
of the EPA limit 1300 µg/L
worst single sample: 1210 µg/L
94/95 SYR4 2013–2017
Nitrate
1350 µg/L 14%
of the EPA limit 10000 µg/L
worst single sample: 1380 µg/L
58/60 SYR4 2012–2019
Dibromoacetic Acid
2.535 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
54/131 SYR4 2012–2019
Monochloroacetic Acid
4.7 µg/L
No EPA limit set
worst single sample: 5.4 µg/L
49/131 SYR4 2012–2019
Trichloroacetic Acid
2 µg/L
No EPA limit set
worst single sample: 97.3 µg/L
41/131 SYR4 2012–2019
Lead
8.287 µg/L 55%
of the EPA limit 15 µg/L
worst single sample: 37.6 µg/L
40/95 SYR4 2013–2017
Bromoform
6.132 µg/L
No EPA limit set
worst single sample: 13.6 µg/L
29/148 SYR4 2012–2019
Monobromoacetic Acid
1.5 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
21/131 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Barium
69.45 µg/L 3.5%
of the EPA limit 2000 µg/L
worst single sample: 74 µg/L
8/8 SYR4 2016–2019
Fluoride
1722.5 µg/L 43%
of the EPA limit 4000 µg/L
worst single sample: 1920 µg/L
6/6 SYR4 2014–2017
Nitrate-Nitrite
1372.5 µg/L 14%
of the EPA limit 10000 µg/L
worst single sample: 1380 µg/L
6/6 SYR4 2012–2015
Arsenic
4.48 µg/L 45%
of the EPA limit 10 µg/L
worst single sample: 5 µg/L
5/8 SYR4 2016–2019
Atrazine
0.1086 µg/L 3.6%
of the EPA limit 3 µg/L
worst single sample: 0.1100 µg/L
5/22 SYR4 2012–2019
Cyanide
59.945 µg/L 30%
of the EPA limit 200 µg/L
worst single sample: 60.5 µg/L
4/6 SYR4 2014–2017
Chromium
3.08 µg/L 3.1%
of the EPA limit 100 µg/L
worst single sample: 3.2 µg/L
4/8 SYR4 2016–2019
Lithium
20.8 µg/L
No EPA limit set
2/10 UCMR-5 2024
Antimony, Total
0.9100 µg/L 15%
of the EPA limit 6 µg/L
1/8 SYR4 2016–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
Dichloromethane
0.6300 µg/L 13%
of the EPA limit 5 µg/L
1/18 SYR4 2014–2019
Gross Beta Particle Activity
6.4 pCi/L
No EPA limit set
1/3 SYR4 2017
Mercury
0.1380 µg/L 6.9%
of the EPA limit 2 µg/L
1/8 SYR4 2016–2019
78 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WILSON, HENRY
Phone
817-788-7000
Email
mayor.wilson@hursttx.gov

Frequently asked questions about City of Hurst

Is City of Hurst tap water safe to drink?

EPA monitoring detected 31 contaminants in City of Hurst's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Hurst's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Hurst serve?

City of Hurst reports serving 40,454 people in Texas, per its EPA record.

Has City of Hurst had any water quality violations?

The EPA has 16 violations on file for City of Hurst, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.