← Texas

Tap water quality report

City of Everman

EPA monitoring tested this supplier for 109 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
20
detected
6,279
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Tarrant

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
29
violations on file
2
still open
ViolationTypeStatusPeriod
RPT Monitoring Unaddressed 2025-07-02
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Resolved 2023-11-05
Other Monitoring Resolved 2023-11-05
MR Monitoring Resolved 2022-09-08
MR Monitoring Resolved 2022-09-08
MR Monitoring Resolved 2022-09-08
MR Monitoring Resolved 2022-09-08
Other Monitoring Resolved 2022-06-25
Other Monitoring Resolved 2022-06-25

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
190 µg/L 15%
of the EPA limit 1300 µg/L
63/64 SYR4 2013–2017
Nitrate
686 µg/L 6.9%
of the EPA limit 10000 µg/L
60/66 SYR4 2012–2019
Bromoform
6.41 µg/L
No EPA limit set
56/64 SYR4 2012–2019
Dibromochloromethane
5.2 µg/L
No EPA limit set
43/64 SYR4 2012–2019
TTHM
13.7 µg/L 17%
of the EPA limit 80 µg/L
43/44 SYR4 2012–2019
Bromodichloromethane
2.7 µg/L
No EPA limit set
16/64 SYR4 2012–2019
Monochloroacetic Acid
5.8 µg/L
No EPA limit set
16/44 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.9 µg/L 12%
of the EPA limit 60 µg/L
16/44 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Nitrate-Nitrite
686 µg/L 6.9%
of the EPA limit 10000 µg/L
10/13 SYR4 2012–2015
Barium
16 µg/L 0.8%
of the EPA limit 2000 µg/L
8/8 SYR4 2016–2019
Chromium
7.2 µg/L 7.2%
of the EPA limit 100 µg/L
8/8 SYR4 2016–2019
Fluoride
1790 µg/L 45%
of the EPA limit 4000 µg/L
8/8 SYR4 2014–2017
Lithium
86 µg/L
No EPA limit set
8/8 UCMR-5 2023
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2016
Selenium
1.8 µg/L 3.6%
of the EPA limit 50 µg/L
4/8 SYR4 2016–2019
Lead
2.1 µg/L 14%
of the EPA limit 15 µg/L
3/64 SYR4 2013–2017
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
2/44 SYR4 2012–2019
Arsenic
0.7100 µg/L 7.1%
of the EPA limit 10 µg/L
1/8 SYR4 2016–2019
Chloroform
1.2 µg/L
No EPA limit set
1/64 SYR4 2012–2019
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RICHARDSON, RAY
Phone
817-690-6519

Frequently asked questions about City of Everman

Is City of Everman tap water safe to drink?

EPA monitoring detected 20 contaminants in City of Everman's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Everman's water?

EPA monitoring detected Copper, Nitrate, Bromoform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does City of Everman serve?

City of Everman reports serving 6,279 people in Texas, per its EPA record.

Has City of Everman had any water quality violations?

The EPA has 29 violations on file for City of Everman, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.