← Texas

Tap water quality report

Heights Water

EPA monitoring tested this supplier for 75 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
18
detected
306
people served
120
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Smith

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

120
health-based violations
254
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
64.385 µg/L
No EPA limit set
worst single sample: 70.8 µg/L
28/28 SYR4 2012–2019
Bromodichloromethane
23.47 µg/L
No EPA limit set
worst single sample: 25.1 µg/L
27/28 SYR4 2012–2019
Dibromochloromethane
7.9875 µg/L
No EPA limit set
worst single sample: 8.07 µg/L
26/28 SYR4 2012–2019
Dichloroacetic Acid
24.46 µg/L
No EPA limit set
worst single sample: 26.2 µg/L
22/22 SYR4 2012–2019
TTHM
95.765 µg/L 120%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 101 µg/L
22/22 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
43.465 µg/L 72%
of the EPA limit 60 µg/L
worst single sample: 53 µg/L
22/22 SYR4 2012–2019
Trichloroacetic Acid
18.3 µg/L
No EPA limit set
worst single sample: 25.9 µg/L
21/22 SYR4 2012–2019
Nitrate
827 µg/L 8.3%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
176.5 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 190 µg/L
10/11 SYR4 2014–2017
Dibromoacetic Acid
3.12 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
10/22 SYR4 2012–2019
Lead
0.0015 mg/L 10%
of the EPA limit 0.0150 mg/L
7/7 LCR 2026
Monochloroacetic Acid
3 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
6/22 SYR4 2012–2019
Fluoride
829.8 µg/L 21%
of the EPA limit 4000 µg/L
worst single sample: 834 µg/L
3/3 SYR4 2012–2018
Barium
18.95 µg/L 0.9%
of the EPA limit 2000 µg/L
worst single sample: 19 µg/L
2/2 SYR4 2016–2019
Nitrate-Nitrite
38.735 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 38.8 µg/L
2/2 SYR4 2014–2019
Arsenic
0.7700 µg/L 7.7%
of the EPA limit 10 µg/L
1/2 SYR4 2016–2019
Lead
1.5 µg/L 10%
of the EPA limit 15 µg/L
1/11 SYR4 2014–2017
Monobromoacetic Acid
3 µg/L
No EPA limit set
1/22 SYR4 2012–2019
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NEELY, JACK
Phone
903-566-2754
Email
JACKNEELY2015@GMAIL.COM

Frequently asked questions about Heights Water

Is Heights Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Heights Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Heights Water's water?

EPA monitoring detected Chloroform, Bromodichloromethane, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Heights Water serve?

Heights Water reports serving 306 people in Texas, per its EPA record.

Has Heights Water had any water quality violations?

The EPA has 254 violations on file for Heights Water, of which 120 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.