← Texas

Tap water quality report

Lindale Rural Wsc Dc

EPA monitoring tested this supplier for 79 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
23
detected
3,876
people served
2
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Smith

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1991-08-01 → 1991-08-31
MCL Health-based Archived 1991-04-01 → 1991-04-30
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
44 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 63 µg/L
44/52 SYR4 2012–2019
Chloroform
10.039 µg/L
No EPA limit set
worst single sample: 16.2 µg/L
28/29 SYR4 2012–2019
Copper
241 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 256 µg/L
24/25 SYR4 2014–2017
Bromodichloromethane
10.517 µg/L
No EPA limit set
worst single sample: 16.1 µg/L
23/29 SYR4 2012–2019
Dibromochloromethane
9.42 µg/L
No EPA limit set
worst single sample: 12.3 µg/L
21/29 SYR4 2012–2019
Lead
1.3 µg/L 8.7%
of the EPA limit 15 µg/L
worst single sample: 1.4 µg/L
11/25 SYR4 2014–2017
TTHM
40.6 µg/L 51%
of the EPA limit 80 µg/L
worst single sample: 46.4 µg/L
9/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
7.9 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 9.3 µg/L
9/9 SYR4 2013–2019
Dichloroacetic Acid
3.535 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
8/9 SYR4 2013–2019
Fluoride
231.2 µg/L 5.8%
of the EPA limit 4000 µg/L
worst single sample: 266 µg/L
7/7 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Nitrate-Nitrite
43.7 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 44 µg/L
7/10 SYR4 2012–2015
Barium
86.5 µg/L 4.3%
of the EPA limit 2000 µg/L
worst single sample: 87 µg/L
6/6 SYR4 2014–2018
Bromoform
1.6625 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
6/29 SYR4 2012–2019
Chromium
1.8 µg/L 1.8%
of the EPA limit 100 µg/L
5/6 SYR4 2014–2018
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2012–2015
Di(2-ethylhexyl) Phthalate
7.26 µg/L 121%
of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 8.4 µg/L
4/16 SYR4 2016–2019
Trichloroacetic Acid
2.335 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
4/9 SYR4 2013–2019
Xylenes, Total
2.9595 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 3.15 µg/L
4/20 SYR4 2012–2019
Monobromoacetic Acid
3.255 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
2/9 SYR4 2013–2019
Dibromoacetic Acid
2.6 µg/L
No EPA limit set
1/9 SYR4 2013–2019
Ethylbenzene
0.5100 µg/L 0.1%
of the EPA limit 700 µg/L
1/20 SYR4 2012–2019
Gross Beta Particle Activity
5.5 pCi/L
No EPA limit set
1/5 SYR4 2012–2018
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KLING III, PAUL
Phone
903-882-3335
Email
paul@lindaleruralwater.com

Frequently asked questions about Lindale Rural Wsc Dc

Is Lindale Rural Wsc Dc tap water safe to drink?

EPA monitoring detected 23 contaminants in Lindale Rural Wsc Dc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lindale Rural Wsc Dc's water?

EPA monitoring detected Nitrate, Chloroform, Copper, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Lindale Rural Wsc Dc serve?

Lindale Rural Wsc Dc reports serving 3,876 people in Texas, per its EPA record.

Has Lindale Rural Wsc Dc had any water quality violations?

The EPA has 4 violations on file for Lindale Rural Wsc Dc, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.