← Texas

Tap water quality report

City of Hearne

EPA monitoring tested this supplier for 109 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
24
detected
4,959
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Robertson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
69
violations on file
1
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-01-01 → 2023-03-31
MR Monitoring Resolved 2023-01-01 → 2023-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Unaddressed 2013-12-30
MR Monitoring Resolved 2011-06-01
MR Monitoring Resolved 2011-06-01
MR Monitoring Resolved 2011-06-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
166.6 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 412 µg/L
63/68 SYR4 2013–2019
Nitrate
60 µg/L 0.6%
of the EPA limit 10000 µg/L
worst single sample: 110 µg/L
58/64 SYR4 2012–2019
Bromoform
11 µg/L
No EPA limit set
worst single sample: 12.3 µg/L
32/34 SYR4 2013–2019
Dibromochloromethane
6.51 µg/L
No EPA limit set
worst single sample: 9.3 µg/L
32/34 SYR4 2013–2019
Lead
2.898 µg/L 19%
of the EPA limit 15 µg/L
worst single sample: 3.78 µg/L
23/68 SYR4 2013–2019
Bromodichloromethane
3.18 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
22/34 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Nitrate-Nitrite
54.5 µg/L 0.5%
of the EPA limit 10000 µg/L
worst single sample: 60 µg/L
12/12 SYR4 2012–2015
Combined Radium (-226 And -228)
2.25 pCi/L 45%
of the EPA limit 5 pCi/L
worst single sample: 3 pCi/L
11/11 SYR4 2013–2019
Barium
87.695 µg/L 4.4%
of the EPA limit 2000 µg/L
worst single sample: 107 µg/L
10/10 SYR4 2013–2019
Fluoride
439.2 µg/L 11%
of the EPA limit 4000 µg/L
worst single sample: 472 µg/L
9/9 SYR4 2013–2019
TTHM
16.34 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 16.7 µg/L
9/10 SYR4 2013–2019
Chloroform
2.495 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
8/34 SYR4 2013–2019
Lithium
21.3 µg/L
No EPA limit set
8/8 UCMR-5 2024
Total Haloacetic Acids (HAA5)
8.175 µg/L 14%
of the EPA limit 60 µg/L
worst single sample: 8.5 µg/L
6/10 SYR4 2013–2019
Dibromoacetic Acid
3.52 µg/L
No EPA limit set
worst single sample: 3.6 µg/L
5/10 SYR4 2013–2019
Xylenes, Total
0.8850 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 0.9000 µg/L
4/24 SYR4 2014–2019
Di(2-ethylhexyl) Phthalate
21.74 µg/L 362%
of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 24 µg/L
3/22 SYR4 2012–2019
Monochloroacetic Acid
4.225 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
2/10 SYR4 2013–2019
Chromium
7.55 µg/L 7.6%
of the EPA limit 100 µg/L
1/10 SYR4 2013–2019
Dichloroacetic Acid
2.3 µg/L
No EPA limit set
1/10 SYR4 2013–2019
Monobromoacetic Acid
1 µg/L
No EPA limit set
1/10 SYR4 2013–2019
Thallium, Total
0.4310 µg/L 22%
of the EPA limit 2 µg/L
1/10 SYR4 2013–2019
Trichloroacetic Acid
1.3 µg/L
No EPA limit set
1/10 SYR4 2013–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GOMEZ, RUBEN
Phone
979-279-3461

Frequently asked questions about City of Hearne

Is City of Hearne tap water safe to drink?

EPA monitoring detected 24 contaminants in City of Hearne's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Hearne's water?

EPA monitoring detected Copper, Nitrate, Bromoform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does City of Hearne serve?

City of Hearne reports serving 4,959 people in Texas, per its EPA record.

Has City of Hearne had any water quality violations?

The EPA has 69 violations on file for City of Hearne, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.