← Texas

Tap water quality report

West Park Addition

EPA monitoring tested this supplier for 77 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
18
detected
144
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Parker

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
57
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
Other Monitoring Unaddressed 2025-04-28
Other Monitoring Unaddressed 2025-04-28
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2480 µg/L 25%
of the EPA limit 10000 µg/L
24/24 SYR4 2018–2019
Copper
22 µg/L 1.7%
of the EPA limit 1300 µg/L
20/20 SYR4 2019
Arsenic
1.9 µg/L 19%
of the EPA limit 10 µg/L
6/6 SYR4 2018
Barium
110 µg/L 5.5%
of the EPA limit 2000 µg/L
6/6 SYR4 2018
Chromium
1.4 µg/L 1.4%
of the EPA limit 100 µg/L
6/6 SYR4 2018
Combined Uranium
3.6 µg/L 12%
of the EPA limit 30 µg/L
6/6 SYR4 2018
Fluoride
284 µg/L 7.1%
of the EPA limit 4000 µg/L
6/6 SYR4 2018
Gross Beta Particle Activity
7 pCi/L
No EPA limit set
6/6 SYR4 2018
Nitrite
162 µg/L 16%
of the EPA limit 1000 µg/L
6/6 SYR4 2018
Combined Radium (-226 And -228)
1.59 pCi/L 32%
of the EPA limit 5 pCi/L
5/5 SYR4 2018
Gross Alpha, Excl. Radon And U
6 pCi/L 40%
of the EPA limit 15 pCi/L
5/6 SYR4 2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
4/4 LCR 2025
Lead
0.4000 µg/L 2.7%
of the EPA limit 15 µg/L
4/20 SYR4 2019
Bromoform
2.2 µg/L
No EPA limit set
3/25 SYR4 2018–2019
Chloroform
1.8 µg/L
No EPA limit set
2/25 SYR4 2018–2019
Dibromochloromethane
1.7 µg/L
No EPA limit set
1/25 SYR4 2018–2019
Monochloroacetic Acid
16.1 µg/L
No EPA limit set
1/1 SYR4 2019
Total Haloacetic Acids (HAA5)
16.1 µg/L 27%
of the EPA limit 60 µg/L
1/1 SYR4 2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MORGAN, DANIEL
Phone
469-855-9505

Frequently asked questions about West Park Addition

Is West Park Addition tap water safe to drink?

EPA monitoring detected 18 contaminants in West Park Addition's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in West Park Addition's water?

EPA monitoring detected Nitrate, Copper, Arsenic, Barium, Chromium, and others. The full list with the level and data source for each is above.

How many people does West Park Addition serve?

West Park Addition reports serving 144 people in Texas, per its EPA record.

Has West Park Addition had any water quality violations?

The EPA has 57 violations on file for West Park Addition, of which 4 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.