← Texas

Tap water quality report

Parker County Sud Surface

EPA monitoring tested this supplier for 108 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
22
detected
6,300
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Parker

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
2
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2018-12-30
MR Monitoring Resolved 2018-12-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0078 µg/L 2/6 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
297 µg/L 23%
of the EPA limit 1300 µg/L
63/63 SYR4 2012–2018
Bromodichloromethane
16.3 µg/L
No EPA limit set
59/59 SYR4 2012–2019
Dibromochloromethane
23.9 µg/L
No EPA limit set
59/59 SYR4 2012–2019
Chloroform
15.7 µg/L
No EPA limit set
58/59 SYR4 2012–2019
TTHM
71 µg/L 89%
of the EPA limit 80 µg/L
52/52 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
32.1 µg/L 54%
of the EPA limit 60 µg/L
52/52 SYR4 2012–2019
Dichloroacetic Acid
11.9 µg/L
No EPA limit set
51/52 SYR4 2012–2019
Bromoform
40.3 µg/L
No EPA limit set
37/59 SYR4 2012–2019
Dibromoacetic Acid
22.1 µg/L
No EPA limit set
36/52 SYR4 2012–2019
Lead
4.06 µg/L 27%
of the EPA limit 15 µg/L
30/63 SYR4 2012–2018
Trichloroacetic Acid
5 µg/L
No EPA limit set
30/52 SYR4 2012–2019
Monobromoacetic Acid
8.9 µg/L
No EPA limit set
26/52 SYR4 2012–2019
Nitrate
150 µg/L 1.5%
of the EPA limit 10000 µg/L
24/26 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Monochloroacetic Acid
3.9 µg/L
No EPA limit set
11/52 SYR4 2012–2019
Lithium
15.3 µg/L
No EPA limit set
6/6 UCMR-5 2025
Barium
49 µg/L 2.5%
of the EPA limit 2000 µg/L
5/5 SYR4 2015–2019
Fluoride
69 µg/L 1.7%
of the EPA limit 4000 µg/L
5/5 SYR4 2015–2019
Cyanide
100 µg/L 50%
of the EPA limit 200 µg/L
4/5 SYR4 2015–2019
Arsenic
1.4 µg/L 14%
of the EPA limit 10 µg/L
3/5 SYR4 2015–2019
Nitrate-Nitrite
150 µg/L 1.5%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2015
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LEATHERMAN, COLE
Phone
817-594-2900

Frequently asked questions about Parker County Sud Surface

Is Parker County Sud Surface tap water safe to drink?

EPA monitoring detected 22 contaminants in Parker County Sud Surface's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Parker County Sud Surface's water?

EPA monitoring detected Copper, Bromodichloromethane, Dibromochloromethane, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Parker County Sud Surface serve?

Parker County Sud Surface reports serving 6,300 people in Texas, per its EPA record.

Has Parker County Sud Surface had any water quality violations?

The EPA has 2 violations on file for Parker County Sud Surface, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.