← Texas

Tap water quality report

Sturdivant Progress Wsc

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
3,111
people served
7
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Palo Pinto

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
74
violations on file
7
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
TT Health-based Unaddressed 2024-10-17
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MR Monitoring Unaddressed 2025-12-30
Other Monitoring Resolved 2025-05-01
Other Monitoring Resolved 2025-05-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
21.9 µg/L
No EPA limit set
52/52 SYR4 2012–2019
Bromoform
63.5 µg/L
No EPA limit set
52/52 SYR4 2012–2019
Dibromochloromethane
35.7 µg/L
No EPA limit set
52/52 SYR4 2012–2019
Dichloroacetic Acid
18.3 µg/L
No EPA limit set
52/52 SYR4 2012–2019
TTHM
111 µg/L 139%
of the EPA limit, in the worst sample — 80 µg/L
52/52 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
40.2 µg/L 67%
of the EPA limit 60 µg/L
52/52 SYR4 2012–2019
Dibromoacetic Acid
30.9 µg/L
No EPA limit set
51/52 SYR4 2012–2019
Monobromoacetic Acid
4.8 µg/L
No EPA limit set
49/52 SYR4 2012–2019
Chloroform
16.2 µg/L
No EPA limit set
47/52 SYR4 2012–2019
Trichloroacetic Acid
4.8 µg/L
No EPA limit set
31/52 SYR4 2012–2019
Copper
450 µg/L 35%
of the EPA limit 1300 µg/L
27/29 SYR4 2015–2019
Monochloroacetic Acid
4.4 µg/L
No EPA limit set
17/52 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
8/8 LCR 2025
Lead
14 µg/L 93%
of the EPA limit 15 µg/L
8/29 SYR4 2015–2019

Utility contact

Contact
ROYAL, SCOTT
Phone
940-325-6020
Email
spwse241@gmail.com

Frequently asked questions about Sturdivant Progress Wsc

Is Sturdivant Progress Wsc tap water safe to drink?

EPA monitoring detected 14 contaminants in Sturdivant Progress Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sturdivant Progress Wsc's water?

EPA monitoring detected Bromodichloromethane, Bromoform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Sturdivant Progress Wsc serve?

Sturdivant Progress Wsc reports serving 3,111 people in Texas, per its EPA record.

Has Sturdivant Progress Wsc had any water quality violations?

The EPA has 74 violations on file for Sturdivant Progress Wsc, of which 7 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.