← Texas

Tap water quality report

Swift Wsc

EPA monitoring tested this supplier for 79 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
20
detected
2,547
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Nacogdoches

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
14
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2021-10-02
TT Health-based Resolved 2021-10-02
TT Health-based Resolved 2021-10-02
TT Health-based Resolved 2021-10-02
MON Monitoring Resolved 2025-11-01 → 2025-11-30
MON Monitoring Resolved 2025-11-01 → 2025-11-30
MON Monitoring Resolved 2025-11-01 → 2025-11-30
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
60 µg/L 0.6%
of the EPA limit 10000 µg/L
80/80 SYR4 2012–2019
Bromodichloromethane
12.5 µg/L
No EPA limit set
44/44 SYR4 2012–2019
Chloroform
48.1 µg/L
No EPA limit set
44/44 SYR4 2012–2019
Copper
353 µg/L 27%
of the EPA limit 1300 µg/L
24/30 SYR4 2012–2017
Dichloroacetic Acid
14.2 µg/L
No EPA limit set
17/17 SYR4 2013–2019
TTHM
56.5 µg/L 71%
of the EPA limit 80 µg/L
17/17 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
29.1 µg/L 49%
of the EPA limit 60 µg/L
17/17 SYR4 2013–2019
Trichloroacetic Acid
17.7 µg/L
No EPA limit set
17/17 SYR4 2013–2019
Nitrate-Nitrite
57 µg/L 0.6%
of the EPA limit 10000 µg/L
15/15 SYR4 2012–2019
Dibromochloromethane
1.43 µg/L
No EPA limit set
14/44 SYR4 2012–2019
Lead
13 µg/L 87%
of the EPA limit 15 µg/L
14/30 SYR4 2012–2017
Barium
43 µg/L 2.2%
of the EPA limit 2000 µg/L
11/11 SYR4 2012–2019
Fluoride
220 µg/L 5.5%
of the EPA limit 4000 µg/L
11/11 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Chromium
11 µg/L 11%
of the EPA limit 100 µg/L
6/11 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
6/6 SYR4 2012–2018
Monochloroacetic Acid
3 µg/L
No EPA limit set
5/17 SYR4 2013–2019
Cyanide
8.21 µg/L 4.1%
of the EPA limit 200 µg/L
2/10 SYR4 2014–2017
Selenium
2.1 µg/L 4.2%
of the EPA limit 50 µg/L
1/11 SYR4 2012–2019
Xylenes, Total
1.9 µg/L 0%
of the EPA limit 10000 µg/L
1/27 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HUGHES, PAUL
Phone
936-462-7843

Frequently asked questions about Swift Wsc

Is Swift Wsc tap water safe to drink?

EPA monitoring detected 20 contaminants in Swift Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Swift Wsc's water?

EPA monitoring detected Nitrate, Bromodichloromethane, Chloroform, Copper, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Swift Wsc serve?

Swift Wsc reports serving 2,547 people in Texas, per its EPA record.

Has Swift Wsc had any water quality violations?

The EPA has 14 violations on file for Swift Wsc, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.