Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-07-01 → 2009-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 809.75 µg/L 62% of the EPA limit 1300 µg/L
worst single sample: 1740 µg/L | 46/47 | SYR4 | 2016–2019 |
| Chloroform | 327.8 µg/L No EPA limit set
worst single sample: 530.4 µg/L | 45/45 | SYR4 | 2012–2019 |
| TTHM | 96.8 µg/L 121% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 105 µg/L | 31/32 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 24.885 µg/L No EPA limit set
worst single sample: 26.2 µg/L | 30/31 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 53.915 µg/L 90% of the EPA limit 60 µg/L
worst single sample: 57.5 µg/L | 30/31 | SYR4 | 2013–2019 |
| Bromodichloromethane | 37.5425 µg/L No EPA limit set
worst single sample: 41 µg/L | 26/45 | SYR4 | 2012–2019 |
| Nitrate | 117.1 µg/L 1.2% of the EPA limit 10000 µg/L
worst single sample: 118 µg/L | 22/32 | SYR4 | 2012–2019 |
| Dibromochloromethane | 10.52 µg/L No EPA limit set
worst single sample: 10.7 µg/L | 19/45 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 27.82 µg/L No EPA limit set
worst single sample: 30.2 µg/L | 18/31 | SYR4 | 2013–2019 |
| Lead | 2.41 µg/L 16% of the EPA limit 15 µg/L
worst single sample: 3.58 µg/L | 16/47 | SYR4 | 2016–2019 |
| Monochloroacetic Acid | 3 µg/L No EPA limit set | 14/31 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 12.175 µg/L No EPA limit set
worst single sample: 15.4 µg/L | 6/31 | SYR4 | 2013–2019 |
| Fluoride | 403.5 µg/L 10% of the EPA limit 4000 µg/L
worst single sample: 410 µg/L | 6/6 | SYR4 | 2012–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2024 |
| Nitrate-Nitrite | 87.5 µg/L 0.9% of the EPA limit 10000 µg/L
worst single sample: 91 µg/L | 6/6 | SYR4 | 2013–2019 |
| Xylenes, Total | 4.484 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 4.62 µg/L | 5/14 | SYR4 | 2012–2019 |
| Barium | 64.55 µg/L 3.2% of the EPA limit 2000 µg/L
worst single sample: 65 µg/L | 4/4 | SYR4 | 2016–2019 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 4/4 | SYR4 | 2012–2018 |
| Nitrite | 22.88 µg/L 2.3% of the EPA limit 1000 µg/L
worst single sample: 23.5 µg/L | 2/6 | SYR4 | 2013–2019 |
| Cyanide | 14.4 µg/L 7.2% of the EPA limit 200 µg/L | 1/4 | SYR4 | 2014–2017 |
| Chromium | 3.1 µg/L 3.1% of the EPA limit 100 µg/L | 1/4 | SYR4 | 2016–2019 |
| Ethylbenzene | 0.6350 µg/L 0.1% of the EPA limit 700 µg/L | 1/14 | SYR4 | 2012–2019 |
| Hexachlorocyclopentadiene | 0.1000 µg/L 0.2% of the EPA limit 50 µg/L | 1/4 | SYR4 | 2016–2019 |
56 contaminants tested, none detected
Utility contact
Frequently asked questions about Libby Wsc
Is Libby Wsc tap water safe to drink?
EPA monitoring detected 23 contaminants in Libby Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Libby Wsc's water?
EPA monitoring detected Copper, Chloroform, TTHM, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Libby Wsc serve?
Libby Wsc reports serving 513 people in Texas, per its EPA record.
Has Libby Wsc had any water quality violations?
The EPA has 80 violations on file for Libby Wsc, of which 53 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.