← Texas

Tap water quality report

Lone Star Public Water

EPA monitoring tested this supplier for 79 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
21
detected
2,397
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
32
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2021-06-18
MR Monitoring Resolved 2021-06-18
MR Monitoring Resolved 2021-06-18
MR Monitoring Resolved 2021-06-18
Other Monitoring Resolved 2020-10-01
Other Monitoring Resolved 2020-10-01
Other Monitoring Resolved 2019-07-01
Other Monitoring Resolved 2019-07-01
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
150 µg/L 1.5%
of the EPA limit 10000 µg/L
30/32 SYR4 2012–2019
Copper
190 µg/L 15%
of the EPA limit 1300 µg/L
20/25 SYR4 2012–2017
Chloroform
2 µg/L
No EPA limit set
15/21 SYR4 2013–2019
Bromodichloromethane
4.7 µg/L
No EPA limit set
8/21 SYR4 2013–2019
Bromoform
9.1 µg/L
No EPA limit set
8/21 SYR4 2013–2019
Dibromochloromethane
9.8 µg/L
No EPA limit set
8/21 SYR4 2013–2019
Barium
290 µg/L 14%
of the EPA limit 2000 µg/L
7/7 SYR4 2012–2019
Lead
3.7 µg/L 25%
of the EPA limit 15 µg/L
7/25 SYR4 2012–2017
TTHM
2 µg/L 2.5%
of the EPA limit 80 µg/L
7/7 SYR4 2013–2019
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
5/5 SYR4 2013–2015
Combined Radium (-226 And -228)
4.34 pCi/L 87%
of the EPA limit 5 pCi/L
4/4 SYR4 2012–2018
Gross Beta Particle Activity
25.6 pCi/L
No EPA limit set
4/7 SYR4 2012–2019
Xylenes, Total
2.9 µg/L 0%
of the EPA limit 10000 µg/L
4/15 SYR4 2013–2019
Dibromoacetic Acid
1.8 µg/L
No EPA limit set
3/7 SYR4 2013–2019
Fluoride
560 µg/L 14%
of the EPA limit 4000 µg/L
3/7 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
1.8 µg/L 3%
of the EPA limit 60 µg/L
3/7 SYR4 2013–2019
Ethylbenzene
0.6000 µg/L 0.1%
of the EPA limit 700 µg/L
2/15 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
12.3 pCi/L 82%
of the EPA limit 15 pCi/L
2/4 SYR4 2015–2019
Di(2-ethylhexyl) Phthalate
0.7800 µg/L 13%
of the EPA limit 6 µg/L
1/6 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
1/1 LCR 2023
Mercury
0.5400 µg/L 27%
of the EPA limit 2 µg/L
1/7 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDichloroacetic AcidDinosebEthylene DibromideEndrinHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SEQUEIRA, SIMON, O
Phone
281-356-5347
Email
simon@quadvest.com

Frequently asked questions about Lone Star Public Water

Is Lone Star Public Water tap water safe to drink?

EPA monitoring detected 21 contaminants in Lone Star Public Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lone Star Public Water's water?

EPA monitoring detected Nitrate, Copper, Chloroform, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Lone Star Public Water serve?

Lone Star Public Water reports serving 2,397 people in Texas, per its EPA record.

Has Lone Star Public Water had any water quality violations?

The EPA has 32 violations on file for Lone Star Public Water, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.