← Texas

Tap water quality report

Decker Oaks

EPA monitoring tested this supplier for 79 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
14
detected
1,986
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
80
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2020-10-01
Other Monitoring Resolved 2020-10-01
Other Monitoring Resolved 2020-07-01
Other Monitoring Resolved 2020-07-01
Other Monitoring Resolved 2019-07-01
Other Monitoring Resolved 2019-07-01
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1153 µg/L 89%
of the EPA limit 1300 µg/L
30/41 SYR4 2012–2017
Nitrate
90 µg/L 0.9%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Lead
2.08 µg/L 14%
of the EPA limit 15 µg/L
11/41 SYR4 2012–2017
Arsenic
2.8 µg/L 28%
of the EPA limit 10 µg/L
3/3 SYR4 2012–2019
Barium
165 µg/L 8.3%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR 2023
Nitrate-Nitrite
90 µg/L 0.9%
of the EPA limit 10000 µg/L
2/3 SYR4 2012–2015
Bromoform
1.1 µg/L
No EPA limit set
1/13 SYR4 2013–2019
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
1/1 SYR4 2012
Combined Uranium
2.1 µg/L 7%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Dibromochloromethane
1.6 µg/L
No EPA limit set
1/13 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
2 pCi/L 13%
of the EPA limit 15 pCi/L
1/1 SYR4 2018
TTHM
2.7 µg/L 3.4%
of the EPA limit 80 µg/L
1/7 SYR4 2013–2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SEQUEIRA, SIMON, O
Phone
281-356-5347
Email
simon@quadvest.com

Frequently asked questions about Decker Oaks

Is Decker Oaks tap water safe to drink?

EPA monitoring detected 14 contaminants in Decker Oaks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Decker Oaks's water?

EPA monitoring detected Copper, Nitrate, Lead, Arsenic, Barium, and others. The full list with the level and data source for each is above.

How many people does Decker Oaks serve?

Decker Oaks reports serving 1,986 people in Texas, per its EPA record.

Has Decker Oaks had any water quality violations?

The EPA has 80 violations on file for Decker Oaks, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.