Tap water quality report

Montgomery County Mud 47

EPA monitoring tested this supplier for 44 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
14
detected
24,171
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
26
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-02-01 → 2018-02-28
MCL Health-based Resolved 2018-02-01 → 2018-02-28
MCL Health-based Resolved 2018-02-01 → 2018-02-28
MCL Health-based Resolved 2018-02-01 → 2018-02-28
Other Monitoring Resolved 2020-06-25
Other Monitoring Resolved 2020-06-25
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dibromochloromethane
12.8 µg/L
No EPA limit set
102/102 SYR4 2012–2019
TTHM
85.6 µg/L 107%
of the EPA limit, in the worst sample — 80 µg/L
102/102 SYR4 2012–2019
Copper
226 µg/L 17%
of the EPA limit 1300 µg/L
90/90 SYR4 2013–2019
Bromoform
5.8 µg/L
No EPA limit set
84/102 SYR4 2012–2019
Bromodichloromethane
17.9 µg/L
No EPA limit set
73/102 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
48.2 µg/L 80%
of the EPA limit 60 µg/L
65/102 SYR4 2012–2019
Dibromoacetic Acid
4.1 µg/L
No EPA limit set
64/102 SYR4 2012–2019
Chloroform
65 µg/L
No EPA limit set
62/102 SYR4 2012–2019
Dichloroacetic Acid
26.5 µg/L
No EPA limit set
62/102 SYR4 2012–2019
Trichloroacetic Acid
18.1 µg/L
No EPA limit set
61/102 SYR4 2012–2019
Lead
18 µg/L 120%
of the EPA limit, in the worst sample — 15 µg/L
29/90 SYR4 2013–2019
Monochloroacetic Acid
5.4 µg/L
No EPA limit set
19/102 SYR4 2012–2019
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Lithium
19.9 µg/L
No EPA limit set
4/4 UCMR-5 2024
30 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfuna

Utility contact

Contact
CONNETT, HUGH
Phone
281-367-1271
Email
information@woodlandswater.org

Frequently asked questions about Montgomery County Mud 47

Is Montgomery County Mud 47 tap water safe to drink?

EPA monitoring detected 14 contaminants in Montgomery County Mud 47's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Montgomery County Mud 47's water?

EPA monitoring detected Dibromochloromethane, TTHM, Copper, Bromoform, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Montgomery County Mud 47 serve?

Montgomery County Mud 47 reports serving 24,171 people in Texas, per its EPA record.

Has Montgomery County Mud 47 had any water quality violations?

The EPA has 26 violations on file for Montgomery County Mud 47, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.