Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2012-03-01 → 2012-03-31 |
| MCL | Health-based | Resolved | 2012-03-01 → 2012-03-31 |
| MCL | Health-based | Resolved | 2012-03-01 → 2012-03-31 |
| MCL | Health-based | Resolved | 2012-03-01 → 2012-03-31 |
| MON | Monitoring | Resolved | 2017-03-01 → 2017-03-31 |
| MON | Monitoring | Resolved | 2017-03-01 → 2017-03-31 |
| MON | Monitoring | Resolved | 2017-03-01 → 2017-03-31 |
| MON | Monitoring | Resolved | 2017-03-01 → 2017-03-31 |
| MR | Monitoring | Resolved | 2011-10-01 |
| MR | Monitoring | Archived | 1991-06-01 → 1991-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1100 µg/L 85% of the EPA limit 1300 µg/L | 41/43 | SYR4 | 2013–2018 |
| Nitrate | 60 µg/L 0.6% of the EPA limit 10000 µg/L | 24/32 | SYR4 | 2012–2019 |
| Lead | 3.3 µg/L 22% of the EPA limit 15 µg/L | 11/43 | SYR4 | 2013–2018 |
| Fluoride | 190 µg/L 4.8% of the EPA limit 4000 µg/L | 6/6 | SYR4 | 2012–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 5/5 | LCR | 2025 |
| Barium | 106 µg/L 5.3% of the EPA limit 2000 µg/L | 4/4 | SYR4 | 2015–2018 |
| Nitrate-Nitrite | 60 µg/L 0.6% of the EPA limit 10000 µg/L | 4/6 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 2/2 | SYR4 | 2012–2015 |
| Chloroform | 0.5000 µg/L No EPA limit set | 1/18 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 7.1 µg/L 118% of the EPA limit, in the worst sample — 6 µg/L | 1/4 | SYR4 | 2016–2019 |
| Dibromoacetic Acid | 4.5 µg/L No EPA limit set | 1/7 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 8.2 µg/L No EPA limit set | 1/7 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 17.1 µg/L 29% of the EPA limit 60 µg/L | 1/7 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 4.4 µg/L No EPA limit set | 1/7 | SYR4 | 2013–2019 |
65 contaminants tested, none detected
Utility contact
Frequently asked questions about Westwood North Wsc
Is Westwood North Wsc tap water safe to drink?
EPA monitoring detected 14 contaminants in Westwood North Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Westwood North Wsc's water?
EPA monitoring detected Copper, Nitrate, Lead, Fluoride, Lead, and others. The full list with the level and data source for each is above.
How many people does Westwood North Wsc serve?
Westwood North Wsc reports serving 3,186 people in Texas, per its EPA record.
Has Westwood North Wsc had any water quality violations?
The EPA has 10 violations on file for Westwood North Wsc, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.