Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2022-10-01 |
| MR | Monitoring | Resolved | 2022-10-01 |
| MR | Monitoring | Resolved | 2022-10-01 |
| MR | Monitoring | Resolved | 2022-10-01 |
| MR | Monitoring | Resolved | 2019-12-30 |
| MR | Monitoring | Resolved | 2019-12-30 |
| MR | Monitoring | Resolved | 2013-12-30 |
| MR | Monitoring | Resolved | 1992-07-01 → 1993-06-30 |
| Other | Monitoring | Archived | 1992-04-01 → 1992-04-30 |
| MR | Monitoring | Archived | 1992-04-01 → 1992-04-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 370 µg/L 28% of the EPA limit 1300 µg/L | 73/73 | SYR4 | 2012–2019 |
| Lead | 11.9 µg/L 79% of the EPA limit 15 µg/L | 35/73 | SYR4 | 2012–2019 |
| Nitrate | 1000 µg/L 10% of the EPA limit 10000 µg/L | 26/48 | SYR4 | 2012–2019 |
| Dibromochloromethane | 12.5 µg/L No EPA limit set | 25/37 | SYR4 | 2012–2019 |
| Bromodichloromethane | 5.3 µg/L No EPA limit set | 19/37 | SYR4 | 2012–2019 |
| Bromoform | 10.2 µg/L No EPA limit set | 17/37 | SYR4 | 2012–2019 |
| TTHM | 29.9 µg/L 37% of the EPA limit 80 µg/L | 17/17 | SYR4 | 2013–2019 |
| Lead | 0.00083 mg/L 5.5% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2023 |
| Chloroform | 1.92 µg/L No EPA limit set | 8/37 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 8 µg/L 13% of the EPA limit 60 µg/L | 8/17 | SYR4 | 2013–2019 |
| Barium | 189 µg/L 9.5% of the EPA limit 2000 µg/L | 7/7 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 3.8 µg/L No EPA limit set | 7/17 | SYR4 | 2013–2019 |
| Bromate | 23.5 µg/L 235% of the EPA limit, in the worst sample — 10 µg/L | 6/84 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 3.1 pCi/L 62% of the EPA limit 5 pCi/L | 6/6 | SYR4 | 2012–2019 |
| Fluoride | 180 µg/L 4.5% of the EPA limit 4000 µg/L | 6/7 | SYR4 | 2012–2018 |
| Lithium | 21 µg/L No EPA limit set | 6/6 | UCMR-5 | 2023 |
| Dichloroacetic Acid | 2 µg/L No EPA limit set | 4/17 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 8.9 pCi/L No EPA limit set | 4/8 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 750 µg/L 7.5% of the EPA limit 10000 µg/L | 3/6 | SYR4 | 2012–2019 |
| Xylenes, Total | 8.8 µg/L 0.1% of the EPA limit 10000 µg/L | 3/20 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 5.4 pCi/L 36% of the EPA limit 15 pCi/L | 2/5 | SYR4 | 2015–2019 |
| Arsenic | 2.3 µg/L 23% of the EPA limit 10 µg/L | 1/7 | SYR4 | 2012–2019 |
| Ethylbenzene | 1.7 µg/L 0.2% of the EPA limit 700 µg/L | 1/20 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.2 µg/L No EPA limit set | 1/17 | SYR4 | 2013–2019 |
| Selenium | 9.1 µg/L 18% of the EPA limit 50 µg/L | 1/7 | SYR4 | 2012–2019 |
| Thallium, Total | 1.9 µg/L 95% of the EPA limit 2 µg/L | 1/7 | SYR4 | 2012–2019 |
84 contaminants tested, none detected
Utility contact
Frequently asked questions about Southwest Milam Wsc
Is Southwest Milam Wsc tap water safe to drink?
EPA monitoring detected 26 contaminants in Southwest Milam Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Southwest Milam Wsc's water?
EPA monitoring detected Copper, Lead, Nitrate, Dibromochloromethane, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Southwest Milam Wsc serve?
Southwest Milam Wsc reports serving 11,739 people in Texas, per its EPA record.
Has Southwest Milam Wsc had any water quality violations?
The EPA has 10 violations on file for Southwest Milam Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.