← Texas

Tap water quality report

City of Bruceville Eddy

EPA monitoring tested this supplier for 109 contaminants and detected 32. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
32
detected
10,570
people served
3
health-based violations
Water source
SWP
Ownership
Local government
Counties served
McLennan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
20
violations on file
4
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1980-10-17 → 1981-10-16
MCL Health-based Archived 1979-06-18 → 1980-06-17
MCL Health-based Archived 1979-06-18 → 1979-07-17
Other Monitoring Resolved 2026-01-04
Other Monitoring Resolved 2026-01-04
MR Monitoring Unaddressed 2025-12-30
MR Monitoring Resolved 2024-07-01 → 2024-09-30
MR Monitoring Resolved 2024-07-01 → 2024-09-30
MR Monitoring Resolved 2024-07-01 → 2024-09-30
MR Monitoring Resolved 2024-07-01 → 2024-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0052 µg/L 1/8 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
870 µg/L 67%
of the EPA limit 1300 µg/L
64/64 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
46.9 µg/L 78%
of the EPA limit 60 µg/L
55/62 SYR4 2012–2019
Dibromoacetic Acid
15.7 µg/L
No EPA limit set
54/62 SYR4 2012–2019
Lead
10 µg/L 67%
of the EPA limit 15 µg/L
47/64 SYR4 2013–2019
Nitrate
980 µg/L 9.8%
of the EPA limit 10000 µg/L
34/56 SYR4 2012–2019
Bromodichloromethane
48 µg/L
No EPA limit set
33/87 SYR4 2012–2019
Dichloroacetic Acid
24.4 µg/L
No EPA limit set
33/62 SYR4 2012–2019
Chloroform
36.8 µg/L
No EPA limit set
31/87 SYR4 2012–2019
Dibromochloromethane
55 µg/L
No EPA limit set
31/87 SYR4 2012–2019
Bromoform
23 µg/L
No EPA limit set
30/87 SYR4 2012–2019
TTHM
161 µg/L 201%
of the EPA limit, in the worst sample — 80 µg/L
27/62 SYR4 2012–2019
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Atrazine
0.8100 µg/L 27%
of the EPA limit 3 µg/L
12/32 SYR4 2012–2019
Barium
85.8 µg/L 4.3%
of the EPA limit 2000 µg/L
8/8 SYR4 2014–2019
Fluoride
2620 µg/L 66%
of the EPA limit 4000 µg/L
8/8 SYR4 2014–2018
Monochloroacetic Acid
14.1 µg/L
No EPA limit set
8/62 SYR4 2012–2019
Trichloroacetic Acid
8 µg/L
No EPA limit set
8/62 SYR4 2012–2019
Xylenes, Total
1.7 µg/L 0%
of the EPA limit 10000 µg/L
8/26 SYR4 2014–2019
Monobromoacetic Acid
1.5 µg/L
No EPA limit set
6/62 SYR4 2012–2019
Lithium
162 µg/L
No EPA limit set
6/9 UCMR-5 2025
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2013–2019
Nitrate-Nitrite
300 µg/L 3%
of the EPA limit 10000 µg/L
4/8 SYR4 2012–2015
Di(2-ethylhexyl) Phthalate
0.9000 µg/L 15%
of the EPA limit 6 µg/L
3/32 SYR4 2012–2019
Gross Beta Particle Activity
4.6 pCi/L
No EPA limit set
2/9 SYR4 2013–2019
Arsenic
4.4 µg/L 44%
of the EPA limit 10 µg/L
1/8 SYR4 2014–2019
Benzo(A)Pyrene
0.0500 µg/L 25%
of the EPA limit 0.2000 µg/L
1/32 SYR4 2012–2019
Cyanide
40 µg/L 20%
of the EPA limit 200 µg/L
1/7 SYR4 2014–2018
Dichloromethane
0.6000 µg/L 12%
of the EPA limit 5 µg/L
1/26 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
8.7 pCi/L 58%
of the EPA limit 15 pCi/L
1/7 SYR4 2013–2019
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
1/9 SYR4 2012–2018
Selenium
12.7 µg/L 25%
of the EPA limit 50 µg/L
1/8 SYR4 2014–2019
77 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
OWENS, LINDA
Phone
254-859-5964
Email
council1@bruceville-eddy.us

Frequently asked questions about City of Bruceville Eddy

Is City of Bruceville Eddy tap water safe to drink?

EPA monitoring detected 32 contaminants in City of Bruceville Eddy's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Bruceville Eddy's water?

EPA monitoring detected Copper, Total Haloacetic Acids (HAA5), Dibromoacetic Acid, Lead, Nitrate, and others. The full list with the level and data source for each is above.

How many people does City of Bruceville Eddy serve?

City of Bruceville Eddy reports serving 10,570 people in Texas, per its EPA record.

Has City of Bruceville Eddy had any water quality violations?

The EPA has 20 violations on file for City of Bruceville Eddy, of which 3 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.