Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2023-09-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2023-09-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2023-09-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2023-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 8545 µg/L 85% of the EPA limit 10000 µg/L
worst single sample: 10200 µg/L | 106/106 | SYR4 | 2013–2019 |
| Copper | 129 µg/L 9.9% of the EPA limit 1300 µg/L
worst single sample: 138 µg/L | 19/19 | SYR4 | 2013–2018 |
| Lead | 2.051 µg/L 14% of the EPA limit 15 µg/L
worst single sample: 2.27 µg/L | 7/19 | SYR4 | 2013–2018 |
| Arsenic | 8.55 µg/L 86% of the EPA limit 10 µg/L
worst single sample: 8.8 µg/L | 6/6 | SYR4 | 2013–2019 |
| Barium | 52.75 µg/L 2.6% of the EPA limit 2000 µg/L
worst single sample: 53 µg/L | 6/6 | SYR4 | 2013–2019 |
| Chromium | 3 µg/L 3% of the EPA limit 100 µg/L | 6/6 | SYR4 | 2013–2019 |
| Fluoride | 2610 µg/L 65% of the EPA limit 4000 µg/L
worst single sample: 2620 µg/L | 6/6 | SYR4 | 2013–2019 |
| Selenium | 11 µg/L 22% of the EPA limit 50 µg/L | 6/6 | SYR4 | 2013–2019 |
| Bromoform | 2.914 µg/L No EPA limit set
worst single sample: 3.1 µg/L | 5/18 | SYR4 | 2013–2019 |
| Lead | 0.00051 mg/L 3.4% of the EPA limit 0.0150 mg/L | 5/5 | LCR | 2025 |
| Total Haloacetic Acids (HAA5) | 16.96 µg/L 28% of the EPA limit 60 µg/L
worst single sample: 19.4 µg/L | 5/6 | SYR4 | 2013–2018 |
| Dibromoacetic Acid | 2.04 µg/L No EPA limit set
worst single sample: 2.1 µg/L | 4/6 | SYR4 | 2013–2018 |
| Gross Beta Particle Activity | 15.795 pCi/L No EPA limit set
worst single sample: 15.9 pCi/L | 4/4 | SYR4 | 2013–2016 |
| Nitrate-Nitrite | 7996 µg/L 80% of the EPA limit 10000 µg/L
worst single sample: 8000 µg/L | 3/3 | SYR4 | 2013–2018 |
| TTHM | 3.007 µg/L 3.8% of the EPA limit 80 µg/L
worst single sample: 3.1 µg/L | 3/6 | SYR4 | 2013–2018 |
| Atrazine | 0.0991 µg/L 3.3% of the EPA limit 3 µg/L
worst single sample: 0.1000 µg/L | 2/5 | SYR4 | 2013–2019 |
| Combined Uranium | 12.45 µg/L 42% of the EPA limit 30 µg/L
worst single sample: 12.5 µg/L | 2/2 | SYR4 | 2016 |
| Trichloroacetic Acid | 5.34 µg/L No EPA limit set
worst single sample: 5.5 µg/L | 2/6 | SYR4 | 2013–2018 |
| Gross Alpha, Excl. Radon And U | 5 pCi/L 33% of the EPA limit 15 pCi/L | 1/2 | SYR4 | 2016 |
| Monochloroacetic Acid | 19.4 µg/L No EPA limit set | 1/6 | SYR4 | 2013–2018 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about West Roosevelt Mobile Home Park
Is West Roosevelt Mobile Home Park tap water safe to drink?
EPA monitoring detected 20 contaminants in West Roosevelt Mobile Home Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in West Roosevelt Mobile Home Park's water?
EPA monitoring detected Nitrate, Copper, Lead, Arsenic, Barium, and others. The full list with the level and data source for each is above.
How many people does West Roosevelt Mobile Home Park serve?
West Roosevelt Mobile Home Park reports serving 95 people in Texas, per its EPA record.
Has West Roosevelt Mobile Home Park had any water quality violations?
The EPA has 2507 violations on file for West Roosevelt Mobile Home Park, of which 20 are health-based (a contaminant limit or required treatment was breached) and 8 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.