Tap water quality report

Lubbock County Wcid 1

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
465
people served
14
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lubbock

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
112
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Archived 1991-08-14 → 1994-08-13
MCL Health-based Archived 1991-08-14 → 1994-08-13

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromoform
12.95 µg/L
No EPA limit set
worst single sample: 14 µg/L
27/27 SYR4 2012–2019
Dibromochloromethane
11.91 µg/L
No EPA limit set
worst single sample: 15.5 µg/L
27/27 SYR4 2012–2019
TTHM
27.23 µg/L 34%
of the EPA limit 80 µg/L
worst single sample: 40.2 µg/L
27/27 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
16.34 µg/L 27%
of the EPA limit 60 µg/L
worst single sample: 19.2 µg/L
27/27 SYR4 2012–2019
Dibromoacetic Acid
5.47 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
24/27 SYR4 2012–2019
Bromodichloromethane
7.6525 µg/L
No EPA limit set
worst single sample: 8.12 µg/L
22/27 SYR4 2012–2019
Copper
134.5 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 220 µg/L
20/20 SYR4 2017
Dichloroacetic Acid
5.71 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
20/27 SYR4 2012–2019
Trichloroacetic Acid
3 µg/L
No EPA limit set
15/27 SYR4 2012–2019
Chloroform
3.56 µg/L
No EPA limit set
worst single sample: 4.21 µg/L
14/27 SYR4 2012–2019
Monobromoacetic Acid
4.57 µg/L
No EPA limit set
worst single sample: 6 µg/L
12/27 SYR4 2012–2019
Monochloroacetic Acid
5.925 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
6/27 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2023
Lead
1.665 µg/L 11%
of the EPA limit 15 µg/L
worst single sample: 1.7 µg/L
2/20 SYR4 2017

Utility contact

Contact
POWELL, BRANDON
Phone
806-747-3353
Email
BPOWELL@BUFFALOSPRINGSLAKE.NET

Frequently asked questions about Lubbock County Wcid 1

Is Lubbock County Wcid 1 tap water safe to drink?

EPA monitoring detected 14 contaminants in Lubbock County Wcid 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lubbock County Wcid 1's water?

EPA monitoring detected Bromoform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Lubbock County Wcid 1 serve?

Lubbock County Wcid 1 reports serving 465 people in Texas, per its EPA record.

Has Lubbock County Wcid 1 had any water quality violations?

The EPA has 112 violations on file for Lubbock County Wcid 1, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.