← Texas

Tap water quality report

Loma Vista Water

EPA monitoring tested this supplier for 109 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
18
detected
3,720
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Kerr

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-12-20
MR Monitoring Resolved 2023-12-20
MR Monitoring Resolved 2023-12-20
MR Monitoring Resolved 2023-12-20

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
298.45 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 830 µg/L
32/38 SYR4 2014–2017
Nitrate
49 µg/L 0.5%
of the EPA limit 10000 µg/L
worst single sample: 50 µg/L
22/64 SYR4 2012–2019
Lead
0.0031 mg/L 21%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Lead
1.8 µg/L 12%
of the EPA limit 15 µg/L
worst single sample: 2.3 µg/L
11/38 SYR4 2014–2017
Barium
95.655 µg/L 4.8%
of the EPA limit 2000 µg/L
worst single sample: 95.9 µg/L
8/8 SYR4 2014–2017
Fluoride
1626.5 µg/L 41%
of the EPA limit 4000 µg/L
worst single sample: 1630 µg/L
8/8 SYR4 2014–2017
Gross Beta Particle Activity
14.41 pCi/L
No EPA limit set
worst single sample: 15.4 pCi/L
7/7 SYR4 2012–2018
Combined Uranium
4.62 µg/L 15%
of the EPA limit 30 µg/L
worst single sample: 4.7 µg/L
5/5 SYR4 2014–2018
Gross Alpha, Excl. Radon And U
8.4 pCi/L 56%
of the EPA limit 15 pCi/L
worst single sample: 9 pCi/L
5/5 SYR4 2014–2018
Combined Radium (-226 And -228)
3.8155 pCi/L 76%
of the EPA limit 5 pCi/L
worst single sample: 4.03 pCi/L
4/7 SYR4 2012–2018
Nitrate-Nitrite
28.5 µg/L 0.3%
of the EPA limit 10000 µg/L
worst single sample: 30 µg/L
4/12 SYR4 2012–2015
Lithium
69.7 µg/L
No EPA limit set
4/4 UCMR-5 2025
Dibromochloromethane
1.72 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
3/44 SYR4 2012–2019
Dichloroacetic Acid
1.475 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
2/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.475 µg/L 2.5%
of the EPA limit 60 µg/L
worst single sample: 1.5 µg/L
2/10 SYR4 2013–2019
Bromodichloromethane
0.5000 µg/L
No EPA limit set
1/44 SYR4 2012–2019
TTHM
1.8 µg/L 2.3%
of the EPA limit 80 µg/L
1/10 SYR4 2013–2019
Toluene
2.2 µg/L 0.2%
of the EPA limit 1000 µg/L
1/34 SYR4 2012–2019
91 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOLTZ, SCOT, W
Phone
512-990-4400
Email
swfoltz@aquaamerica.com

Frequently asked questions about Loma Vista Water

Is Loma Vista Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Loma Vista Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Loma Vista Water's water?

EPA monitoring detected Copper, Nitrate, Lead, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Loma Vista Water serve?

Loma Vista Water reports serving 3,720 people in Texas, per its EPA record.

Has Loma Vista Water had any water quality violations?

The EPA has 4 violations on file for Loma Vista Water, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.