Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2021-08-14 |
| TT | Health-based | Resolved | 2021-08-14 |
| TT | Health-based | Resolved | 2021-08-14 |
| TT | Health-based | Resolved | 2021-08-14 |
| MR | Monitoring | Resolved | 2023-01-01 → 2023-03-31 |
| MR | Monitoring | Resolved | 2023-01-01 → 2023-03-31 |
| Other | Monitoring | Resolved | 2021-10-21 |
| Other | Monitoring | Resolved | 2021-10-21 |
| MR | Monitoring | Resolved | 2015-04-01 → 2015-06-30 |
| MR | Monitoring | Resolved | 2015-04-01 → 2015-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 370 µg/L 28% of the EPA limit 1300 µg/L
worst single sample: 460 µg/L | 19/20 | SYR4 | 2014–2017 |
| Bromodichloromethane | 15.215 µg/L No EPA limit set
worst single sample: 18.7 µg/L | 18/18 | SYR4 | 2012–2019 |
| Chloroform | 30.305 µg/L No EPA limit set
worst single sample: 30.9 µg/L | 18/18 | SYR4 | 2012–2019 |
| Dibromochloromethane | 9.3505 µg/L No EPA limit set
worst single sample: 10.6 µg/L | 18/18 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 16.57 µg/L No EPA limit set
worst single sample: 19.8 µg/L | 18/18 | SYR4 | 2012–2019 |
| TTHM | 53.07 µg/L 66% of the EPA limit 80 µg/L
worst single sample: 54.6 µg/L | 18/18 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 26.455 µg/L 44% of the EPA limit 60 µg/L
worst single sample: 34.7 µg/L | 18/18 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 7.6 µg/L No EPA limit set | 18/18 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.88 µg/L No EPA limit set
worst single sample: 2 µg/L | 9/18 | SYR4 | 2012–2019 |
| Lead | 0.0021 mg/L 14% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2023 |
| Bromoform | 7.96 µg/L No EPA limit set
worst single sample: 9.4 µg/L | 5/18 | SYR4 | 2012–2019 |
| Lead | 2.88 µg/L 19% of the EPA limit 15 µg/L
worst single sample: 3.2 µg/L | 5/20 | SYR4 | 2014–2017 |
| Monochloroacetic Acid | 6.26 µg/L No EPA limit set
worst single sample: 7.3 µg/L | 5/18 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.1 µg/L No EPA limit set | 1/18 | SYR4 | 2012–2019 |
Utility contact
Frequently asked questions about Oak Grove Texas Wsc
Is Oak Grove Texas Wsc tap water safe to drink?
EPA monitoring detected 14 contaminants in Oak Grove Texas Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Oak Grove Texas Wsc's water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Oak Grove Texas Wsc serve?
Oak Grove Texas Wsc reports serving 670 people in Texas, per its EPA record.
Has Oak Grove Texas Wsc had any water quality violations?
The EPA has 63 violations on file for Oak Grove Texas Wsc, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.