← Texas

Tap water quality report

City of Port Neches

EPA monitoring tested this supplier for 107 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
17
detected
17,043
people served
23
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Jefferson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

23
health-based violations
32
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2015-04-01 → 2015-06-30
MCL Health-based Resolved 2015-04-01 → 2015-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1460 µg/L 112%
of the EPA limit, in the worst sample — 1300 µg/L
234/247 SYR4 2013–2019
Lead
255 µg/L 1700%
of the EPA limit, in the worst sample — 15 µg/L
125/247 SYR4 2013–2019
Chloroform
195 µg/L
No EPA limit set
115/115 SYR4 2012–2019
Bromodichloromethane
28.3 µg/L
No EPA limit set
114/115 SYR4 2012–2019
TTHM
228 µg/L 285%
of the EPA limit, in the worst sample — 80 µg/L
107/107 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
124 µg/L 207%
of the EPA limit, in the worst sample — 60 µg/L
107/107 SYR4 2012–2019
Dichloroacetic Acid
96.1 µg/L
No EPA limit set
106/107 SYR4 2012–2019
Trichloroacetic Acid
18.7 µg/L
No EPA limit set
105/107 SYR4 2012–2019
Monochloroacetic Acid
12.2 µg/L
No EPA limit set
54/107 SYR4 2012–2019
Dibromochloromethane
4.8 µg/L
No EPA limit set
33/115 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Nitrate
220 µg/L 2.2%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Barium
52.6 µg/L 2.6%
of the EPA limit 2000 µg/L
7/7 SYR4 2013–2019
Hexachlorocyclopentadiene
0.3000 µg/L 0.6%
of the EPA limit 50 µg/L
5/11 SYR4 2012–2019
Cyanide
130 µg/L 65%
of the EPA limit 200 µg/L
4/6 SYR4 2014–2019
Atrazine
0.1400 µg/L 4.7%
of the EPA limit 3 µg/L
2/11 SYR4 2012–2019
Nitrite
40 µg/L 4%
of the EPA limit 1000 µg/L
1/1 SYR4 2013
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ARNOLD, ROBERT
Phone
409-719-4204

Frequently asked questions about City of Port Neches

Is City of Port Neches tap water safe to drink?

EPA monitoring detected 17 contaminants in City of Port Neches's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Port Neches's water?

EPA monitoring detected Copper, Lead, Chloroform, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does City of Port Neches serve?

City of Port Neches reports serving 17,043 people in Texas, per its EPA record.

Has City of Port Neches had any water quality violations?

The EPA has 32 violations on file for City of Port Neches, of which 23 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.