← Texas

Tap water quality report

B H P Wsc

EPA monitoring tested this supplier for 44 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
18
detected
6,321
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Hunt

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
60
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2004-12-01 → 2004-12-31
MCL Health-based Resolved 2004-12-01 → 2004-12-31
MCL Health-based Resolved 2004-12-01 → 2004-12-31
MCL Health-based Resolved 2004-12-01 → 2004-12-31
MR Monitoring Resolved 2025-12-30
MR Monitoring Resolved 2025-12-30
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0053 µg/L 3/4 2023
Pfhxa 0.0071 µg/L 3/4 2023
Pfpea 0.0089 µg/L 3/4 2023
Pfba 0.0064 µg/L 2/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1400 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 2520 µg/L
197/200 SYR4 2012–2019
Lead
3.7675 µg/L 25%
of the EPA limit 15 µg/L
worst single sample: 10.5 µg/L
116/199 SYR4 2012–2019
Bromodichloromethane
22.47 µg/L
No EPA limit set
worst single sample: 36.2 µg/L
62/62 SYR4 2012–2019
Chloroform
17.855 µg/L
No EPA limit set
worst single sample: 52.4 µg/L
62/62 SYR4 2012–2019
Dibromochloromethane
14.07 µg/L
No EPA limit set
worst single sample: 21.4 µg/L
62/62 SYR4 2012–2019
Dichloroacetic Acid
14.885 µg/L
No EPA limit set
worst single sample: 27.5 µg/L
62/62 SYR4 2012–2019
TTHM
52.35 µg/L 65%
of the EPA limit 80 µg/L
worst single sample: 113.1 µg/L
62/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
31.02 µg/L 52%
of the EPA limit 60 µg/L
worst single sample: 52.3 µg/L
62/62 SYR4 2012–2019
Trichloroacetic Acid
7.48 µg/L
No EPA limit set
worst single sample: 18.7 µg/L
62/62 SYR4 2012–2019
Bromoform
5.515 µg/L
No EPA limit set
worst single sample: 6.5 µg/L
46/62 SYR4 2012–2019
Dibromoacetic Acid
9.4 µg/L
No EPA limit set
worst single sample: 12.2 µg/L
46/62 SYR4 2012–2019
Monobromoacetic Acid
2.485 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
22/62 SYR4 2012–2019
Monochloroacetic Acid
5.71 µg/L
No EPA limit set
worst single sample: 6.6 µg/L
22/62 SYR4 2012–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
26 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
WHITEHEAD, STEVE
Phone
972-636-2154
Email
bhpwater@sbcglobal.net

Frequently asked questions about B H P Wsc

Is B H P Wsc tap water safe to drink?

EPA monitoring detected 18 contaminants in B H P Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in B H P Wsc's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does B H P Wsc serve?

B H P Wsc reports serving 6,321 people in Texas, per its EPA record.

Has B H P Wsc had any water quality violations?

The EPA has 60 violations on file for B H P Wsc, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.