← Texas

Tap water quality report

City of Commerce

EPA monitoring tested this supplier for 109 contaminants and detected 30. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
30
detected
9,266
people served
86
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Hunt

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

86
health-based violations
150
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
TT Health-based Resolved 2022-07-01 → 2022-07-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0054 µg/L 1/5 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
318.8 µg/L 25%
of the EPA limit 1300 µg/L
worst single sample: 748 µg/L
65/65 SYR4 2013–2017
Chloroform
140.5 µg/L
No EPA limit set
worst single sample: 253 µg/L
54/73 SYR4 2012–2019
Bromodichloromethane
23.795 µg/L
No EPA limit set
worst single sample: 28.3 µg/L
50/73 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
74.675 µg/L 124%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 142 µg/L
50/56 SYR4 2012–2019
Nitrate
970 µg/L 9.7%
of the EPA limit 10000 µg/L
worst single sample: 1200 µg/L
48/48 SYR4 2012–2019
Dichloroacetic Acid
33.135 µg/L
No EPA limit set
worst single sample: 52.6 µg/L
44/56 SYR4 2012–2019
Lead
4.6815 µg/L 31%
of the EPA limit 15 µg/L
worst single sample: 26 µg/L
44/65 SYR4 2013–2017
Trichloroacetic Acid
34.48 µg/L
No EPA limit set
worst single sample: 77.3 µg/L
44/56 SYR4 2012–2019
TTHM
135.4 µg/L 169%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 187 µg/L
43/57 SYR4 2012–2019
Dibromochloromethane
4.88 µg/L
No EPA limit set
worst single sample: 6.2 µg/L
37/73 SYR4 2012–2019
Monochloroacetic Acid
11.42 µg/L
No EPA limit set
worst single sample: 12.1 µg/L
33/56 SYR4 2012–2019
Nitrite
980.6 µg/L 98%
of the EPA limit 1000 µg/L
worst single sample: 1740 µg/L
33/40 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Fluoride
826 µg/L 21%
of the EPA limit 4000 µg/L
worst single sample: 874 µg/L
11/11 SYR4 2012–2019
Atrazine
0.2910 µg/L 9.7%
of the EPA limit 3 µg/L
worst single sample: 0.3000 µg/L
10/16 SYR4 2012–2019
Barium
72.685 µg/L 3.6%
of the EPA limit 2000 µg/L
worst single sample: 75.7 µg/L
10/10 SYR4 2013–2019
Dibromoacetic Acid
1.53 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
8/56 SYR4 2012–2019
Nitrate-Nitrite
1661.5 µg/L 17%
of the EPA limit 10000 µg/L
worst single sample: 1700 µg/L
8/8 SYR4 2012–2019
Monobromoacetic Acid
19.55 µg/L
No EPA limit set
worst single sample: 22.1 µg/L
6/56 SYR4 2012–2019
Chromium
3.6 µg/L 3.6%
of the EPA limit 100 µg/L
worst single sample: 4.1 µg/L
5/10 SYR4 2013–2019
Cyanide
62.85 µg/L 31%
of the EPA limit 200 µg/L
worst single sample: 63.2 µg/L
3/9 SYR4 2014–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
3/3 SYR4 2016
Arsenic
1.49 µg/L 15%
of the EPA limit 10 µg/L
worst single sample: 1.5 µg/L
2/10 SYR4 2013–2019
Dichloromethane
0.7980 µg/L 16%
of the EPA limit 5 µg/L
worst single sample: 0.8100 µg/L
2/17 SYR4 2012–2019
Selenium
5.2 µg/L 10%
of the EPA limit 50 µg/L
worst single sample: 5.4 µg/L
2/10 SYR4 2013–2019
Lithium
38.3 µg/L
No EPA limit set
2/5 UCMR-5 2025
Bromoform
1.54 µg/L
No EPA limit set
1/73 SYR4 2012–2019
Carbon Tetrachloride
0.9000 µg/L 18%
of the EPA limit 5 µg/L
1/17 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
5.7 µg/L 95%
of the EPA limit 6 µg/L
1/16 SYR4 2012–2019
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranChlordaneCombined UraniumDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
REEL, TEDDY
Phone
903-886-1100
Email
DRFrancis@aquaamerica.com

Frequently asked questions about City of Commerce

Is City of Commerce tap water safe to drink?

EPA monitoring detected 30 contaminants in City of Commerce's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Commerce's water?

EPA monitoring detected Copper, Chloroform, Bromodichloromethane, Total Haloacetic Acids (HAA5), Nitrate, and others. The full list with the level and data source for each is above.

How many people does City of Commerce serve?

City of Commerce reports serving 9,266 people in Texas, per its EPA record.

Has City of Commerce had any water quality violations?

The EPA has 150 violations on file for City of Commerce, of which 86 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.