← Texas

Tap water quality report

Military Hwy Wsc Progreso

EPA monitoring tested this supplier for 109 contaminants and detected 27. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
27
detected
12,198
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Hidalgo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2015-10-01
MR Monitoring Resolved 2011-03-17
MR Monitoring Resolved 2011-03-17
MR Monitoring Resolved 2011-03-17
MR Monitoring Resolved 2011-03-17
Other Monitoring Resolved 2003-05-01
MR Monitoring Resolved 2003-01-01 → 2003-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
4970 µg/L 382%
of the EPA limit, in the worst sample — 1300 µg/L
128/128 SYR4 2012–2017
Bromoform
44.9 µg/L
No EPA limit set
99/99 SYR4 2012–2019
Dibromochloromethane
34.6 µg/L
No EPA limit set
99/99 SYR4 2012–2019
Dibromoacetic Acid
9.5 µg/L
No EPA limit set
94/94 SYR4 2012–2019
TTHM
85.1 µg/L 106%
of the EPA limit, in the worst sample — 80 µg/L
94/94 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
14.4 µg/L 24%
of the EPA limit 60 µg/L
94/94 SYR4 2012–2019
Lead
14 µg/L 93%
of the EPA limit 15 µg/L
77/128 SYR4 2012–2017
Bromodichloromethane
14.7 µg/L
No EPA limit set
32/99 SYR4 2012–2019
Chloroform
5.3 µg/L
No EPA limit set
12/99 SYR4 2012–2019
Dichloroacetic Acid
4.2 µg/L
No EPA limit set
12/94 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Nitrate
150 µg/L 1.5%
of the EPA limit 10000 µg/L
10/40 SYR4 2012–2019
Fluoride
1090 µg/L 27%
of the EPA limit 4000 µg/L
6/6 SYR4 2013–2019
Gross Beta Particle Activity
10.3 pCi/L
No EPA limit set
6/6 SYR4 2012–2018
Trichloroacetic Acid
3.4 µg/L
No EPA limit set
6/94 SYR4 2012–2019
Arsenic
7.7 µg/L 77%
of the EPA limit 10 µg/L
5/5 SYR4 2012–2019
Barium
37.8 µg/L 1.9%
of the EPA limit 2000 µg/L
5/5 SYR4 2012–2019
Nitrate-Nitrite
150 µg/L 1.5%
of the EPA limit 10000 µg/L
5/10 SYR4 2012–2015
Combined Uranium
11.6 µg/L 39%
of the EPA limit 30 µg/L
4/4 SYR4 2015–2018
Selenium
27.6 µg/L 55%
of the EPA limit 50 µg/L
4/5 SYR4 2012–2019
Lithium
92.9 µg/L
No EPA limit set
4/4 UCMR-5 2025
Gross Alpha, Excl. Radon And U
6 pCi/L 40%
of the EPA limit 15 pCi/L
3/4 SYR4 2015–2018
Combined Radium (-226 And -228)
1.6 pCi/L 32%
of the EPA limit 5 pCi/L
2/6 SYR4 2012–2018
Monochloroacetic Acid
7.9 µg/L
No EPA limit set
2/94 SYR4 2012–2019
Chromium
6.73 µg/L 6.7%
of the EPA limit 100 µg/L
1/5 SYR4 2012–2019
Monobromoacetic Acid
1.4 µg/L
No EPA limit set
1/94 SYR4 2012–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
1/10 SYR4 2012–2015
82 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SANCHEZ, SANTIAGO
Phone
956-565-2491
Email
mhwsc@aol.com

Frequently asked questions about Military Hwy Wsc Progreso

Is Military Hwy Wsc Progreso tap water safe to drink?

EPA monitoring detected 27 contaminants in Military Hwy Wsc Progreso's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Military Hwy Wsc Progreso's water?

EPA monitoring detected Copper, Bromoform, Dibromochloromethane, Dibromoacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Military Hwy Wsc Progreso serve?

Military Hwy Wsc Progreso reports serving 12,198 people in Texas, per its EPA record.

Has Military Hwy Wsc Progreso had any water quality violations?

The EPA has 13 violations on file for Military Hwy Wsc Progreso, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.