Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromoform | 71.01 µg/L No EPA limit set
worst single sample: 74.8 µg/L | 38/44 | SYR4 | 2012–2019 |
| Chloroform | 5.06 µg/L No EPA limit set
worst single sample: 6.37 µg/L | 38/44 | SYR4 | 2012–2019 |
| Bromodichloromethane | 15.94 µg/L No EPA limit set
worst single sample: 21.2 µg/L | 37/44 | SYR4 | 2012–2019 |
| Dibromochloromethane | 48.22 µg/L No EPA limit set
worst single sample: 68.7 µg/L | 37/44 | SYR4 | 2012–2019 |
| Nitrate | 371.95 µg/L 3.7% of the EPA limit 10000 µg/L
worst single sample: 412 µg/L | 30/32 | SYR4 | 2012–2019 |
| TTHM | 141.4 µg/L 177% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 165.6 µg/L | 29/32 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 32.68 µg/L 54% of the EPA limit 60 µg/L
worst single sample: 39.3 µg/L | 29/32 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 19.445 µg/L No EPA limit set
worst single sample: 20.7 µg/L | 28/32 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 2.74 µg/L No EPA limit set
worst single sample: 3.5 µg/L | 25/32 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 3.37 µg/L No EPA limit set
worst single sample: 4.1 µg/L | 23/32 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 3.185 µg/L No EPA limit set
worst single sample: 4.5 µg/L | 22/32 | SYR4 | 2012–2019 |
| Copper | 424.7 µg/L 33% of the EPA limit 1300 µg/L
worst single sample: 542 µg/L | 18/19 | SYR4 | 2013–2017 |
| Lead | 6.69 µg/L 45% of the EPA limit 15 µg/L
worst single sample: 8.01 µg/L | 16/19 | SYR4 | 2013–2017 |
| Monochloroacetic Acid | 9.4 µg/L No EPA limit set
worst single sample: 10.3 µg/L | 11/32 | SYR4 | 2012–2019 |
| Barium | 17.75 µg/L 0.9% of the EPA limit 2000 µg/L
worst single sample: 18 µg/L | 6/6 | SYR4 | 2013–2019 |
| Fluoride | 306.25 µg/L 7.7% of the EPA limit 4000 µg/L
worst single sample: 310 µg/L | 6/6 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2023 |
| Chromium | 4.12 µg/L 4.1% of the EPA limit 100 µg/L
worst single sample: 4.6 µg/L | 4/6 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 1.475 pCi/L 30% of the EPA limit 5 pCi/L
worst single sample: 1.5 pCi/L | 2/2 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 64.98 µg/L 0.6% of the EPA limit 10000 µg/L
worst single sample: 65.4 µg/L | 2/2 | SYR4 | 2014–2019 |
| Cyanide | 63.4 µg/L 32% of the EPA limit 200 µg/L | 1/4 | SYR4 | 2014–2017 |
| Thallium, Total | 0.5780 µg/L 29% of the EPA limit 2 µg/L | 1/6 | SYR4 | 2013–2019 |
57 contaminants tested, none detected
Utility contact
Frequently asked questions about C R C Wsc
Is C R C Wsc tap water safe to drink?
EPA monitoring detected 22 contaminants in C R C Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in C R C Wsc's water?
EPA monitoring detected Bromoform, Chloroform, Bromodichloromethane, Dibromochloromethane, Nitrate, and others. The full list with the level and data source for each is above.
How many people does C R C Wsc serve?
C R C Wsc reports serving 723 people in Texas, per its EPA record.
Has C R C Wsc had any water quality violations?
The EPA has 93 violations on file for C R C Wsc, of which 74 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.