Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2015-04-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-04-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-04-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-04-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-04-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-01-01 → 2015-03-31 |
| MCL | Health-based | Resolved | 2015-01-01 → 2015-03-31 |
| MCL | Health-based | Resolved | 2015-01-01 → 2015-03-31 |
| MCL | Health-based | Resolved | 2015-01-01 → 2015-03-31 |
| MCL | Health-based | Resolved | 2015-01-01 → 2015-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 30 µg/L No EPA limit set | 41/41 | SYR4 | 2012–2019 |
| Dibromochloromethane | 75.1 µg/L No EPA limit set | 41/41 | SYR4 | 2012–2019 |
| Chloroform | 10.4 µg/L No EPA limit set | 40/41 | SYR4 | 2012–2019 |
| Bromoform | 116.4 µg/L No EPA limit set | 37/41 | SYR4 | 2012–2019 |
| TTHM | 217.8 µg/L 272% of the EPA limit, in the worst sample — 80 µg/L | 35/35 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 71.1 µg/L 118% of the EPA limit, in the worst sample — 60 µg/L | 35/35 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 52.2 µg/L No EPA limit set | 33/35 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 49.4 µg/L No EPA limit set | 33/35 | SYR4 | 2012–2019 |
| Nitrate | 4030 µg/L 40% of the EPA limit 10000 µg/L | 32/32 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 5 µg/L No EPA limit set | 32/35 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 5.5 µg/L No EPA limit set | 28/35 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 12 µg/L No EPA limit set | 14/35 | SYR4 | 2012–2019 |
| Copper | 260 µg/L 20% of the EPA limit 1300 µg/L | 10/11 | SYR4 | 2015–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2024 |
| Nitrate-Nitrite | 320 µg/L 3.2% of the EPA limit 10000 µg/L | 6/6 | SYR4 | 2012–2015 |
| Lead | 2.7 µg/L 18% of the EPA limit 15 µg/L | 3/11 | SYR4 | 2015–2018 |
| Arsenic | 1.1 µg/L 11% of the EPA limit 10 µg/L | 2/2 | SYR4 | 2016–2019 |
| Barium | 160 µg/L 8% of the EPA limit 2000 µg/L | 2/2 | SYR4 | 2016–2019 |
| Cyanide | 147 µg/L 74% of the EPA limit 200 µg/L | 2/2 | SYR4 | 2016–2019 |
| Fluoride | 762 µg/L 19% of the EPA limit 4000 µg/L | 2/2 | SYR4 | 2016–2019 |
| Gross Beta Particle Activity | 9.7 pCi/L No EPA limit set | 2/2 | SYR4 | 2016–2019 |
| Antimony, Total | 0.2500 µg/L 4.2% of the EPA limit 6 µg/L | 1/2 | SYR4 | 2016–2019 |
| Chromium | 1.1 µg/L 1.1% of the EPA limit 100 µg/L | 1/2 | SYR4 | 2016–2019 |
| Combined Uranium | 1.4 µg/L 4.7% of the EPA limit 30 µg/L | 1/2 | SYR4 | 2016–2019 |
| Selenium | 2.5 µg/L 5% of the EPA limit 50 µg/L | 1/2 | SYR4 | 2016–2019 |
53 contaminants tested, none detected
Utility contact
Frequently asked questions about Paint Creek Wsc
Is Paint Creek Wsc tap water safe to drink?
EPA monitoring detected 25 contaminants in Paint Creek Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Paint Creek Wsc's water?
EPA monitoring detected Bromodichloromethane, Dibromochloromethane, Chloroform, Bromoform, TTHM, and others. The full list with the level and data source for each is above.
How many people does Paint Creek Wsc serve?
Paint Creek Wsc reports serving 290 people in Texas, per its EPA record.
Has Paint Creek Wsc had any water quality violations?
The EPA has 123 violations on file for Paint Creek Wsc, of which 36 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.