← Texas

Tap water quality report

Blocker Crossroads Wsc

EPA monitoring tested this supplier for 79 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
25
detected
1,836
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Harrison

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
122
violations on file
1
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2026-02-16
MON Monitoring Resolved 2024-12-01 → 2024-12-31
MON Monitoring Resolved 2024-12-01 → 2024-12-31
MON Monitoring Resolved 2024-12-01 → 2024-12-31
MON Monitoring Resolved 2023-12-01 → 2023-12-31
MON Monitoring Resolved 2023-12-01 → 2023-12-31
MON Monitoring Resolved 2023-12-01 → 2023-12-31
MON Monitoring Resolved 2023-12-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
438 µg/L 4.4%
of the EPA limit 10000 µg/L
30/32 SYR4 2012–2019
Bromoform
41.9 µg/L
No EPA limit set
26/32 SYR4 2012–2019
Dibromochloromethane
35.8 µg/L
No EPA limit set
26/32 SYR4 2012–2019
Bromodichloromethane
13.4 µg/L
No EPA limit set
25/32 SYR4 2012–2019
Chloroform
5.23 µg/L
No EPA limit set
22/32 SYR4 2012–2019
TTHM
90.6 µg/L 113%
of the EPA limit, in the worst sample — 80 µg/L
18/22 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
33.2 µg/L 55%
of the EPA limit 60 µg/L
18/22 SYR4 2012–2019
Copper
180 µg/L 14%
of the EPA limit 1300 µg/L
16/18 SYR4 2012–2019
Dibromoacetic Acid
11.7 µg/L
No EPA limit set
14/22 SYR4 2012–2019
Dichloroacetic Acid
3.4 µg/L
No EPA limit set
10/22 SYR4 2012–2019
Trichloroacetic Acid
1.7 µg/L
No EPA limit set
8/22 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Monobromoacetic Acid
2 µg/L
No EPA limit set
7/22 SYR4 2012–2019
Fluoride
300 µg/L 7.5%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
Monochloroacetic Acid
23.5 µg/L
No EPA limit set
6/22 SYR4 2012–2019
Barium
210 µg/L 11%
of the EPA limit 2000 µg/L
5/5 SYR4 2012–2018
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2012–2018
Di(2-ethylhexyl) Phthalate
1.2 µg/L 20%
of the EPA limit 6 µg/L
4/11 SYR4 2014–2019
Chromium
8.63 µg/L 8.6%
of the EPA limit 100 µg/L
2/5 SYR4 2012–2018
Lead
0.4800 µg/L 3.2%
of the EPA limit 15 µg/L
2/18 SYR4 2012–2019
Nitrate-Nitrite
359 µg/L 3.6%
of the EPA limit 10000 µg/L
2/2 SYR4 2014
Arsenic
0.7860 µg/L 7.9%
of the EPA limit 10 µg/L
1/5 SYR4 2012–2018
Benzo(A)Pyrene
0.1800 µg/L 90%
of the EPA limit 0.2000 µg/L
1/11 SYR4 2014–2019
Gross Beta Particle Activity
8.8 pCi/L
No EPA limit set
1/4 SYR4 2012–2018
Selenium
3.7 µg/L 7.4%
of the EPA limit 50 µg/L
1/5 SYR4 2012–2018
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MASON, MIKE, J
Phone
903-633-2250
Email
waterdepartment2019@gmail.com

Frequently asked questions about Blocker Crossroads Wsc

Is Blocker Crossroads Wsc tap water safe to drink?

EPA monitoring detected 25 contaminants in Blocker Crossroads Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blocker Crossroads Wsc's water?

EPA monitoring detected Nitrate, Bromoform, Dibromochloromethane, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Blocker Crossroads Wsc serve?

Blocker Crossroads Wsc reports serving 1,836 people in Texas, per its EPA record.

Has Blocker Crossroads Wsc had any water quality violations?

The EPA has 122 violations on file for Blocker Crossroads Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.