Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2025-06-01 → 2025-06-30 |
| TT | Health-based | Resolved | 2025-06-01 → 2025-06-30 |
| TT | Health-based | Resolved | 2025-06-01 → 2025-06-30 |
| TT | Health-based | Resolved | 2025-06-01 → 2025-06-30 |
| TT | Health-based | Resolved | 2022-03-01 → 2022-03-31 |
| TT | Health-based | Resolved | 2022-03-01 → 2022-03-31 |
| TT | Health-based | Resolved | 2022-03-01 → 2022-03-31 |
| TT | Health-based | Resolved | 2022-03-01 → 2022-03-31 |
| TT | Health-based | Resolved | 2021-02-01 → 2021-02-28 |
| TT | Health-based | Resolved | 2021-02-01 → 2021-02-28 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfpea | 0.0072 µg/L | 1/3 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 26.39 µg/L No EPA limit set
worst single sample: 34.5 µg/L | 115/115 | SYR4 | 2012–2019 |
| Chloroform | 80.68 µg/L No EPA limit set
worst single sample: 132.3 µg/L | 115/115 | SYR4 | 2012–2019 |
| Dibromochloromethane | 6.32 µg/L No EPA limit set
worst single sample: 10.9 µg/L | 113/115 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 40.15 µg/L No EPA limit set
worst single sample: 51.4 µg/L | 107/107 | SYR4 | 2012–2019 |
| TTHM | 104.14 µg/L 130% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 160.7 µg/L | 107/107 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 68.41 µg/L 114% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 98.6 µg/L | 107/107 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 23.81 µg/L No EPA limit set
worst single sample: 42.1 µg/L | 107/107 | SYR4 | 2012–2019 |
| Copper | 147.5 µg/L 11% of the EPA limit 1300 µg/L
worst single sample: 750 µg/L | 86/95 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 4.825 µg/L No EPA limit set
worst single sample: 6.5 µg/L | 68/107 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.24 µg/L No EPA limit set
worst single sample: 2.5 µg/L | 33/107 | SYR4 | 2012–2019 |
| Lead | 22.4 µg/L 149% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 45 µg/L | 27/95 | SYR4 | 2013–2019 |
| Nitrate | 301 µg/L 3% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 0.0021 mg/L 14% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2022 |
| Fluoride | 506.9 µg/L 13% of the EPA limit 4000 µg/L
worst single sample: 530 µg/L | 8/8 | SYR4 | 2012–2019 |
| Barium | 65 µg/L 3.3% of the EPA limit 2000 µg/L
worst single sample: 71 µg/L | 7/7 | SYR4 | 2013–2019 |
| Cyanide | 42.1145 µg/L 21% of the EPA limit 200 µg/L
worst single sample: 43.9 µg/L | 2/6 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2017 |
| Monobromoacetic Acid | 1.2 µg/L No EPA limit set | 1/107 | SYR4 | 2012–2019 |
| Nitrite | 22 µg/L 2.2% of the EPA limit 1000 µg/L | 1/1 | SYR4 | 2013 |
| Selenium | 2.27 µg/L 4.5% of the EPA limit 50 µg/L | 1/7 | SYR4 | 2013–2019 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Marshall
Is City of Marshall tap water safe to drink?
EPA monitoring detected 21 contaminants in City of Marshall's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Marshall's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.
How many people does City of Marshall serve?
City of Marshall reports serving 23,091 people in Texas, per its EPA record.
Has City of Marshall had any water quality violations?
The EPA has 146 violations on file for City of Marshall, of which 65 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.