← Texas

Tap water quality report

Harris County Mud 374 Cypress Creek Lake

EPA monitoring tested this supplier for 44 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
16
detected
5,526
people served
0
health-based violations
Water source
GWP
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2011-02-01 → 2011-02-28
MR Monitoring Resolved 2011-02-01 → 2011-02-28
MR Monitoring Resolved 2011-02-01 → 2011-02-28

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0060 µg/L 3/4 2024
Pfhxa 0.0046 µg/L 2/4 2024
Pfpea 0.0043 µg/L 2/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
14.6 µg/L
No EPA limit set
37/37 SYR4 2013–2019
Chloroform
40.1 µg/L
No EPA limit set
37/37 SYR4 2013–2019
Dibromoacetic Acid
3.9 µg/L
No EPA limit set
37/37 SYR4 2013–2019
Dibromochloromethane
6.4 µg/L
No EPA limit set
37/37 SYR4 2013–2019
Dichloroacetic Acid
42.1 µg/L
No EPA limit set
37/37 SYR4 2013–2019
TTHM
51.9 µg/L 65%
of the EPA limit 80 µg/L
37/37 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
61.8 µg/L 103%
of the EPA limit, in the worst sample — 60 µg/L
37/37 SYR4 2013–2019
Trichloroacetic Acid
16.5 µg/L
No EPA limit set
37/37 SYR4 2013–2019
Copper
1400 µg/L 108%
of the EPA limit, in the worst sample — 1300 µg/L
33/40 SYR4 2014–2017
Lead
9.1 µg/L 61%
of the EPA limit 15 µg/L
16/40 SYR4 2014–2017
Monochloroacetic Acid
6.8 µg/L
No EPA limit set
7/37 SYR4 2013–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
6/6 LCR 2023
Bromoform
2.2 µg/L
No EPA limit set
4/37 SYR4 2013–2019
28 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaMonobromoacetic AcidNetfosaaNfdhaNmefosaaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
SYKES, JOE
Phone
713-860-6400

Frequently asked questions about Harris County Mud 374 Cypress Creek Lake

Is Harris County Mud 374 Cypress Creek Lake tap water safe to drink?

EPA monitoring detected 16 contaminants in Harris County Mud 374 Cypress Creek Lake's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harris County Mud 374 Cypress Creek Lake's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromoacetic Acid, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Harris County Mud 374 Cypress Creek Lake serve?

Harris County Mud 374 Cypress Creek Lake reports serving 5,526 people in Texas, per its EPA record.

Has Harris County Mud 374 Cypress Creek Lake had any water quality violations?

The EPA has 3 violations on file for Harris County Mud 374 Cypress Creek Lake, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.